Installation manual
© Hills Industries 2009 Page 46
Feature 68 new Configuration Group 1 Characteristic Select
Segment 1
1
Fire (turn on if this is a fire zone)
2
24 hour (turn on for non-fire 24 hour zones)
3
Key-switch zone (normally open switch)
4
Follower (turn on for burglary zones that are Instant during non-entry times)
(5)
Delay 1 zone (follows timer 1 entry and exit times)
6
Delay 2 zone (follows timer 2 entry and exit times)
7
Reserved
8
Local only (turn on if this zone should not be reported)
Segment 2
1
On if configuration group will beep the code pad for alarm
(2)
On if configuration group will sound the yelping siren for alarm
3
On if configuration group will sound the steady (temporal) siren for alarm
4
On if configuration group will chime
(5)
On if configuration group can be bypassed
6
On if configuration group is included in the Group Bypass
(7)
On if configuration group is Force Arm
(8)
On if configuration group is Active in Partial Mode
Segment 3
1
Reserved
(2)
On enables Double End Of Line (DEOL) Tamper Zone
3
On enables Trouble Reporting zone (Day Zones and Fire Zones)
4
On if configuration group is a Twin Trip Zone
(5)
On enables Dialer Delay Zone
(6)
On if configuration group will siren / communicator attempt count
(7)
On enables Restore reporting
(8) new
Reserved
Segment 4 new
1 new
Zone Activity Monitor (also see F25 – Seg 11 – Opt 11 and F22 – Seg 6 – Opt 3 to the set timer, and
Zone Tamper Reporting must also be enabled in F9 – Seg 1 – Opt 7)
2 new
EOL Resistor Defeat (if enabled, a short = seal, open circuit = unseal)
3 new
Request To Exit (REX button) (triggers Request To Exit event for NX508E Output Expander board)
4 new
Access Control (applies to NX1701EAU reader, triggers DOTL and Forced Door access violations for
NX508E Output Expander board)
5 new
Reserved
6 new
Reserved
7 new
Reserved
8 new
Reserved
Segment 5 new
1 new
Reserved
2 new
Reserved
3 new
Reserved
4 new
Reserved
5 new
Reserved
6 new
Reserved
7 new
Reserved
8 new
Reserved