Installation manual
© Hills Industries 2009 Page 45
Feature 62 Zone Area Select - Zones 25-32
Feature 62 is used to select the area(s) that zones 25-32 reside in. A zone may reside in any combination of the eight
areas. If a burglary zone resides in more than one area, it will only be active when all areas are armed. A zone that resides
in more than one area will be reported to its lowest area. Feature 62 has 8 segments. Segment 1 corresponds to zone 25
and Segment 8 corresponds to zone 32.
Refer to Feature 60 in this section for the zone area select table.
Feature 63 Zones 33-40 Configuration Group
Segments 1-8
16 16 16 16 16 16 16 16
Feature 63 contains the Configuration Group (zone type) for zones 33-40. Segment 1 is for zone 33, and Segment 8 is for
zone 40.
Feature 64 Zone Area Select - Zones 33-40
Feature 64 is used to select the area(s) that zones 33-40 reside in. A zone may reside in any combination of the eight
areas. If a burglary zone resides in more than one area, it will only be active when all areas are armed. A zone that resides
in more than one area will be reported to its lowest area. Feature 64 has 8 segments. Segment 1 corresponds to zone 33
and Segment 8 corresponds to zone 40.
Refer to Feature 60 in this section for the zone area select table.
Feature 65 Zones 41-48 Configuration Group
Segments 1-8
16 16 16 16 16 16 16 16
Feature 65 contains the Configuration Group (zone type) for zones 41-48. Segment 1 is zone 41, and Segment 8 is zone
48.
Feature 66 Zone Area Select - Zones 41-48
Feature 66 is used to select the area(s) that zones 41-48 reside in. A zone may reside in any combination of the eight
areas. If a burglary zone resides in more than one area, it will only be active when all areas are armed. A zone that resides
in more than one area will be reported to its lowest area. Feature 66 has 8 segments. Segment 1 corresponds to zone 41
and Segment 8 corresponds to zone 48.
Refer to Feature 60 in this section for the zone area select table.
Configuration Groups 1 – 20
Features 67-106 are used to change the zone configurations as listed in the Default Zone Configuration Table in zones 1 to
128 configuration section. These features are considered advanced programming and should only be changed with a
thorough understanding of the operation of each bit.
Feature 67 Configuration Group 1 Alarm Event Code
Segment 1 3
Feature 67 contains the Contact I.D. event code sent for zone configuration group 1 alarm reports. The desired event code
should be chosen from the Contact I.D. Configuration Group Event Table in the Appendix section.