Installation manual
© Hills Industries 2009 Page 43
Feature 48 Area 5 – Option and Report Selections
Feature 48 is used to enable certain options that can be accessed or are visible to the user from the code pad of the
system. In addition, certain communicator reports are enabled. Each of these options can be enabled by area 5.
If the option selection feature for any area is left blank, that area will use Feature 16 for the option selection. Refer
to Feature 39 in this section for options table.
Feature 49 new Area 5 – Entry / Exit Timers
Entry Time 1 Exit Time 1 Entry Time 2 Exit Time 2
Segments 1-6 30 60 30 60
Reserved new Reserved new
Feature 49 sets the primary and secondary entry / exit times for area 5. If all segments in this feature are set to ‘0’, the
entry / exit time for this area will follow area 1 (Feature 17). Valid entries are 10-255 seconds
Feature 50 new Area 6 – Account Code
Segments 1-6 10 10 10 10 Reserved new Reserved new
Feature 50 contains the account code sent when area 6 is reported. If Feature 50 is left as default (all ‘10’s), then the
system account code (Feature 5) will be used.
Feature 51 Area 6 – Option and Report Selections
Feature 51 is used to enable certain options that can be accessed or are visible to the user from the code pad of the
system. In addition, certain communicator reports are enabled. Each of these options can be enabled by area 6.
If the option selection feature for any area is left blank, that area will use Feature 16 for the option selection. Refer
to Feature 39 in this section for options table.
Feature 52 new Area 6 – Entry / Exit Timers
Entry Time 1 Exit Time 1 Entry Time 2 Exit Time 2
Segments 1-6 30 60 30 60
Reserved new Reserved new
Feature 52 sets the primary and secondary entry / exit times for area 6. If all segments in this feature are set to ‘0’, the
entry / exit time for this area will follow area 1 (Feature 17). Valid entries are 10-255 seconds
Feature 53 new Area 7 – Account Code
Segments 1-6 10 10 10 10 Reserved new Reserved new
Feature 53 contains the account code sent when area 7 is reported. If Feature 53 is left as default (all ‘10’s), then the
system account code (Feature 5) will be used.
Feature 54 Area 7 – Option and Report Selections
Feature 54 is used to enable certain options that can be accessed or are visible to the user from the code pad of the
system. In addition, certain communicator reports are enabled. Each of these options can be enabled by area 7.
If the option selection feature for any area is left blank, that area will use Feature 16 for the option selection. Refer
to Feature 39 in this section for options table.
Feature 55 new Area 7 – Entry / Exit Timers
Entry Time 1 Exit Time 1 Entry Time 2 Exit Time 2
Segments 1-6 30 60 30 60
Reserved new Reserved new
Feature 55 sets the primary and secondary entry / exit times for area 7. If all segments in this Feature are set to ‘0’, the
entry / exit time for this area will follow area 1 (Feature 17). Valid entries are 10-255 seconds.