Installation manual
© Hills Industries 2009 Page 32
Feature 21 Zone Area Select - Zones 9-16
Feature 21 is used to select the area(s) that zones 9-16 reside in. A zone may reside in any combination of the eight areas.
If a burglary zone resides in more than one area, it will only be active when all areas are armed. A zone that resides in
more than one area will be reported to its lowest area. Feature 21 has 8 segments. Segment 1 corresponds to zone 9 and
Segment 8 corresponds to zone 16.
Area 1 Area 2 Area 3 Area 4 Area 5 Area 6 Area 7 Area 8
Segment 1 – Zone 9 (1) 2 3 4 5 6 7 8
Segment 2 – Zone 10 (1) 2 3 4 5 6 7 8
Segment 3 – Zone 11 (1) 2 3 4 5 6 7 8
Segment 4 – Zone 12 (1) 2 3 4 5 6 7 8
Segment 5 – Zone 13 (1) 2 3 4 5 6 7 8
Segment 6 – Zone 14 (1) 2 3 4 5 6 7 8
Segment 7 – Zone 15 (1) 2 3 4 5 6 7 8
Segment 8 – Zone 16 (1) 2 3 4 5 6 7 8
Feature 22 new System Options new
Feature 22 is used to enable various system option and reporting options.
Segment 1
(1)
On if siren sounds for ‘Telephone Line Cut’ when armed
2
On if siren sounds for ‘Telephone Line Cut’ when disarmed
3
On if siren blast at arming – (A siren chirp when any area is armed)
4
On if siren blast at exit expiration – (A siren chirp when any area exit delay expires)
5
On if siren blast at closing kiss-off – (A siren chirp when any area sends a closing report)
(6)
On if siren limited to once per zone
7
On if siren sounds for any Tamper
(8)
On if siren blasts 1 time for key-switch and wireless arming; 2 times for disarming
(when using NX-148E in master mode on a multi-area system, siren blasts on all area disarm)
Segment 2
1
On if siren driver should be a voltage output. Off = speaker output.
2
On if sirens should sound on expander trouble
3
On if Communicator limited to once per zone
4
On if First to Open Last to Close Reports
5
On if Battery Missing Test is performed every 12 seconds
(6)
On if Strobe flashes for 3 seconds for key-switch and wireless arming, 6 seconds for disarming
7
On if Manual Communicator Test performed during []-[44] test function
(8)
On if Box Tamper Pins on the control panel are enabled
Segment 3
(1)
On if Box Tamper reporting enabled
(2)
On if AC Fail reporting enabled
(3)
On if Low Battery reporting enabled
(4)
On if Aux Power Over-current reporting enabled
(5)
On if Siren Supervision reporting enabled
(6)
On if Telephone Line Cut reporting enabled
7
Reserved
(8)
On if Expander Trouble reporting enabled