Area Option Descriptions
Re-exit
The panel has the ability to restart the exit delay if required without disarming the system by pressing the [Exit] key while
the system is running the exit delay. This option can only be used once per arming cycle.
Silent Auto-Arming
If enabled, the panel will Auto-Arm this area and not activate the 50 second code pad sound. This option is used when you
don’t want to alert any other area of your Auto-Arm time.
Universal Arming
When enabled, using the quick arm function (ON button on code pad) or entering a valid user code will arm the panel in
Partial mode if an exit zone is not faulted during the exit delay time.
Zone Bypassed Sounder Alert
If this option is enabled, the panel will beep the Code Pad sounder upon arming if a zone is bypassed.
Late To Close Reports new
If this option is enabled, the panel will send a Late To Close report to the central monitoring station if Contact ID is enabled
in Feature 6 and the panel has not been armed by the Closing Time in Feature 34.
Auto-Arm In Partial new
If this option is enabled and Auto-Arming is enabled in Feature 36 then the panel will Auto-Arm that area in partial mode at
the Closing Time set in Feature 34.
Disable Bypass For Force Arm Zones new
If this option is enabled then at the end of the Exit Delay if any Force Arm type zones are unsealed they will not be
bypassed and the zone will activate the alarm as per its Zone Configuration Type characteristic.
Feature 17 new Area 1 – Entry / Exit Timers
Entry Time 1 Exit Time 1 Entry Time 2 Exit Time 2
Segments 1-6 30 60 30 60
Reserved new Reserved new
Feature 17 sets the primary and secondary entry / exit times for area 1. Valid entries are 10-255 seconds
Zones 1 – 8 Configuration
Feature 18 Zones 1-8 Configuration Group
Segments 1-8 3 7 16 16 16 16 16 16
Feature 18 contains the Configuration Group (zone type) for zones 1-8. Segment 1 is for zone 1, and Segment 8 is for zone
8. Refer to the ‘Default Zone Configuration’ table in this section for zone type selections.
Default Zone Configurations
Zones can be programmed to be one of 32 different zone configurations (zone types). Configurations 1 to 20 can be
modified in the configuration group section of this manual. Configuration groups 21 to 31 are factory set and cannot be
altered. Choose one of the 30 default zone configurations to program into each of the zone configuration segments (e.g.
features 18, 20, 59, 61, 63, 65, 119, 121, etc). Study this table for the appropriate zone configuration group for each zone.
Data Default Zone Configuration
0 new Zone Disabled
1
Entry / Exit Delay 1: Partial – Forced Arming – A trip will start entry delay 1. This zone will be
active in partial mode. This zone type may be faulted while arming if forced arming is enabled in the
area options.
2
Entry / Exit Delay 1: Chime – Forced Arming – A trip will start entry delay 1. This zone will be
bypassed in partial mode. This zone type will set the code pad chime if set via the code pad [Chime]
key.
3
Entry / Exit Delay 1: Partial – Chime – Forced Arming – A trip will start entry delay 1. This zone
will be active in partial mode. This zone type may be faulted while arming if forced arming is enabled
in the area options. This zone type will set the code pad chime if set via the code pad [Chime] key.