Installation manual
© Hills Industries 2009 Page 19
10. Walk Test Mode - Function [] [Chime]
Step 1 Press the []-[Chime] keys
Step 2
Enter a [Master Arm/Disarm Code]
Now all zones become 24 hour, silent and local (non reporting zones). By faulting any zone, that zone will
latch its zone light on the LED code pad, and sound the Chime. The Chime will continue to sound each
time a zone is faulted. Once all zone are tested (zone lights lit on the LED code pad) go to step 3.
Step 3 Enter a [Master Arm/Disarm Code]
11. Call Back Download [] [9] [8] and Answer Call [] [9] [9]
Step 1
Pressing []-[9]-[8] while the system is disarmed will cause the control panel to initiate a call back for a
download connection (remote access). Note: a valid user code may be required after []-[9]-[8] if
enabled in Feature 0.
Pressing []-[9]-[9] while the system is disarmed will cause the control panel to seize the phone line for
a download connection (remote access). Note: a valid user code may be required after []-[9]-[9] if
enabled in Feature 0.