Installation manual

© Hills Industries 2009 Page 18
9. Assigning User Code Authority Levels - Function [6]
Step 1
Assign user codes before assigning authority levels
Step 2 Press the []-[6] key
Step 3
Enter a [Master Arm/Disarm Code]
Note: a user changing the authority of another user can only add or remove area authorization for areas
to which they have access.
Step 4
The ready light will flash
Step 5
Enter the 2 digit ‘user number’ to be assigned authority.
(The ready light is constant and the partial light will flash).
Step 6
Lights illuminated indicate the authority levels assigned to this code. You may toggle (turn on/off) the
authority level by pressing the number for that authority level. An explanation of the lights is listed below:
LED Attributes if LED 8 is off LED Attributes if LED 8 is on
1
Reserved
1
Activate output 1
2
Arm Only
2
Activate output 2
3
Arm Only After Close Window
3
Activate output 3
4
Master arm/disarm (can program
other codes)
4
Activate output 4
5
Arm/disarm code
5
Arm/disarm
6
Allowed to bypass zones (see F23)
6
Bypass zones
7
Code will send open / close reports
7
Open / Close reporting
8
If LED 8 is off, LEDs 1-7 will use the
details in this column
8
If LED 8 is on, LEDs 1-7 will use the
details in this column
Note you cannot set attributes on both sides of the table above (e.g. Arm Only and Activate output 3).
Step 7
Press the [] key. The ready light will flash. This moves you to the area enable.
(The user has access to areas that are illuminated by the LEDs.)
Step 8
The illuminated numbers indicate each area where the user has access. To change any of the areas
where the user has access, press numbers corresponding to areas where you want to give the user
access or deny access. Refer to chart shown below:
LED Areas Assigned LED Areas Assigned
1
Area 1
5
Area 5
2
Area 2
6
Area 6
3
Area 3
7
Area 7
4
Area 4
8
Area 8
Example: If zone LED 2 is lit, then the user is assigned access to area 2. By pressing the [2] key, the
light will go off, denying access to area 2.
Step 9
When the areas are assigned, press the [] key, returning you to Step 4. You may then enter another
user number to assign authority level. Repeat Steps 4 - 8 until you have assigned authority levels to all
user numbers.
Step 10 Press the [#] key to exit the Assigning Authority Level Program.
Note: Any master arm/disarm code can add or change a user code if the master code has access to the same areas as the
code being added/changed. Consequently, when programming the user codes for such a system, leave at least one code
(can be ‘Go To Program Code’ if enabled in Feature 2) access to all areas or you will not be able to add new users. If you
desire the end user to be able to add new codes, you must remove the area authority from all blank codes.