Installation manual
3
ABCDEFGH I JKLMNOPQRSTUVWXYZ [ ¥ ] ^ _ `
abcdef
g
hi jklmnopqrstuvwx
y
z{|}
!
"#$%&' ( )U +, - . /0123456789: ;<=>?@
• ä µ < ×¢£Ý ö ! ü M $ = ÷
NX-148 LIBRARY
ALARM DELAY EXTERIOR HOUSE MICROWAVE ROOM SMOKE UP
AREA DEN FIRE INFRARED MOTION RUMPUS SOUND UTILITY
AUDIO DETECTOR FRONT INSTANT NORTH SAFE SOUTH VAULT
BACK DINING GAME INTERIOR NURSERY SENSOR STAIRS WAREHOUSE
BATHROOM DOOR GARAGE JUNK OFFICE SHOCK STORAGE WEST
BEAM DOWN GLASSBREAK KITCHEN PANIC SHOP STUDY WINDOW
BEDROOM DURESS GUEST LIBRARY PANTRY SIDE TAMPER WING
BUTTON EAST HALL LIGHT PHONE SKYLIGHT TELEVISION WIRELESS
CEILING EMERGENCY HEAT LIVING PIR SLIDING TROUBLE YARD
CLOSET EXIT HOLDUP MASTER PORCH SMALL TV ZONE
LOADING FACTORY DEFAULTS
To load the factory defaults, enter the Program Mode using the procedure on page 2, then type [
9
]-[
1
]-[
0
]-[
#
]. The
keypad will beep 3 times indicatin
g
that the loadin
g
is in pro
g
ress. The loadin
g
takes about 6 seconds. To load the
factory defaults for the LCD keypad, enter the Program Mode from a
different
keypad (does not have to be LCD
keypad), and follow the procedures mentioned previously.
ENROLLING MODULES AND KEYPADS
For supervision purposes, the NetworX control panel has the ability to automatically find and store in its memory the
presence of all keypads, zone expanders, wireless receivers, and any other module connected to the data terminal.
This allows these modules to be supervised by the control panel.
NOTE
: All modules should be connected and set
to unique addresses prior to enrollin
g
modules. To enroll the modules, enter the Pro
g
ram Mode of the NetworX
control panel. When the Program Mode is exited, the control will enroll the devices. The enrolling process takes
about 12 seconds, during which time the "Service Screen" will be displayed. Once a module is enrolled, if it is not
detected by the control, the "Service Screen” will be displayed.
PROGRAMMING THE NX-148 LCD KEYPADS
This section describes how to pro
g
ram the address and partition of each keypad, as well as the options that are
available. The address of the keypad is important because this is how the panel supervises the keypads. The factory
default for the Master code is [
1
]-[
2
]-[
3
]-[
4
] when usin
g
a 4-di
g
it code, or [
1
]-[
2
]-[
3
]-[
4
]-[
5
]-[
6
] for a 6-digit code. The
factory default for the "Go To Program" code is [
9
]-[
7
]-[
1
]-[
3
] when using a 4-digit code, or [
9
]-[
7
]-[
1
]-[
3
]-[
0
]-[
0
] for a
6-digit code.
[
U
]-[9]-[1] ADJUSTING THE VIEW / BRIGHTNESS OF THE LCD
1) Enter [
U
]-[
9
]-[
1
]
The LCD Screen will prompt for the "Go To Pro
g
ram" code.
2) Enter [
master code
]
The LCD will now prompt you to raise or lower the viewing angle. Using the scroll
keys to the ri
g
ht of the LCD, you can raise or lower the viewin
g
an
g
le of the text.
3) To advance to the
Brightness option, press
[
U
]
The LCD will prompt you to brighten or dim the LCD lighting. Use the scroll keys
a
g
ain to adjust to desired bri
g
htness. When completed, exit by pressin
g
[
U
].