Installation manual

8
LED
ATTRIBUTES IF LED 8 IS OFF LED ATTRIBUTES IF LED 8 IS ON
1 Reserved 1 Activate output #1
2 Arm Only 2 Activate output # 2
3 Arm Only After Close Window 3 Activate output # 3
4 Master arm/disarm (can program other codes) 4 Activate output # 4
5 Arm/disarm code 5 Arm/disarm
6 Allowed to bypass zones (see Feature 23) 6 Bypass Zones
7 Code will send open / close reports 7 Open / Close Reporting
8
If this LED is on, LEDs 1-7 will use the chart to the right
8
If this LED is off, LEDs 1-7 use the chart to the left
Step 7 Press the [*] key. The ready light will flash. This moves you to the area enable. (The user has access in areas that
are illuminated.)
Step 8
The illuminated numbers indicate each area where the user has access. To change any of the areas where the user
has access, press numbers corresponding to areas where you want to give the user access or deny access.
(Example: If zone light #2 is lit, then the user is assigned access to area #2. By pressing the [2] key, the light will go
off, denying access to area #2. Refer to chart shown below.
LIGHT AREAS ASSIGNED LIGHT AREAS ASSIGNED
1 Area 1 5 Area 5
2 Area 2 6 Area 6
3 Area 3 7 Area 7
4 Area 4 8 Area 8
Step 9 When the areas are assigned, press the [*] key. This returns you to Step 4. At this point you may enter another
user number to assign authority level. Repeat Continue Steps 4 - 8 until you have assigned authority levels to all
user numbers.
Step 10
Press the [#] key to exit the Assigning Authority Level Program.
WALK TEST MODE - Function [*] [chime]
Step 1 Press the [*] key.
Step 2 Press the [Chime] key.
Step 3 Enter a “Master Arm/Disarm Code”.
Now all zones become 24 hour, silent and local (non reporting zones). By faulting any zone, that zone will latch its zone light on
the LED code pad, and sound the Chime. The Chime will continue to sound each time a zone is faulted. Once all zone are test
(zone lights lit on the LED code pad) go to step 4.
Step 4 Enter a “Master Arm/Disarm Code”.
FUNCTION [rr]-[9]-[8] Pressing [rr]-[9]-[8] while the system is disarmed will cause the control to do a callback for a download.
NOTE: A VALID USER CODE MAY BE REQUIRED AFTER [r]-[9]-[8] IF ENABLED IN FEATURE 0.
FUNCTION [rr]-[9]-[9] Pressing [rr]-[9]-[9] while the system is disarmed will cause the control panel to seize the phone line for
a download. NOTE: A VALID USER CODE MAY BE REQUIRED AFTER [r]-[9]-[9] IF ENABLED IN 0.
NOTE: Any master arm/disarm code can add or change a user code if the master code has access to the same areas as the
code being added/changed. Consequently, when programming the user codes for such a system, leave at least one code (can
be "go to program code" if enabled in Feature 2) access to all areas or you will not be able to add new users. If you desire the
end user to be able to add new codes, you must remove the area authority from all blank codes.