Installation manual
5
PROGRAMMING THE NX-16 LED CODE PADS
This section describes how to program the address and area of each code pad as well as the options that are
available. The address of the code pad is important because this is how the panel supervises the code pads. The
factory default for the Master code is [1]-[2]-[3]-[4] when using a 4-digit code or [1]-[2]-[3]-[4]-[5]-[6] for a 6-digit
code. The factory default for the "Go To Program" code is [9]-[7]-[1]-[3] for a 4-digit code or [9]-[7]-[1]-[3]-[0]-[0] for
a 6-digit code.
SETTING THE LED CODE STARTING ZONE - Function [9][2]
Step 1 Your system must be in the Disarmed state to program the code pad settings.
Step 2
Press the [r][9]-[2] key.
Step 3 Enter the [program code]
Step 4 Enter the STARTING zone number from 1 to 48.
Step 5
Press [r] - Press [r] to save changes and exit this function.
SETTING THE LED CODE PAD OPTIONS- Function [9][3]
Step 1 Your system must be in the Disarmed state to program the code pad settings.
Step 2
Press the [r] [9]-[3] key
Step 3 Enter the [program code]- The "Service" LED will flash.
LEDs 1-8 can now be toggled on/off to enable/disable the functions listed in the table below:
Step 4
Press [r] - After enabling/disabling the desired functions press [r] to save changes and exit this function.
LED Code Pad Option Enabled
1 Enable Code Pad tamper switch
2 Enable Silent Code Pad option
3 Enable Ding Dong sound for Chime - If off, chime will be a single tone.
4 Enable Key-press Silence option (silences the pulsing code pad sounder for 5 seconds when a key is pressed)
5 Enable Armed Status Suppression (will not allow the code pad to display faulted or bypassed zones when the
system is armed)
6 Enable Panic, Fire, Medical Beep-tone (will sound a short beep to verify that the key-press was accepted)
7 Suppresses the "Service" LED (will not allow the "Service" LED to illuminate for any reason. If there is a system
trouble, pressing [r]-[2] will still show the service menu.)
8
Enable multi-area viewing (enables temporary viewing of all areas by pressing [r]-[1]-[area number])