Installation manual
36
Features 67-106 are used to change the zone configurations as listed in the Default Zone Configuration Table in
Zones 1 to 16 configuration section. These features are considered advanced programming and should only be
changed with a thorough understanding of the operation of each bit.
FEATURE 67 CONFIGURATION GROUP 1 ALARM EVENT CODE
SEGMENT 1
3
Feature 67 contains the Contact I.D event code sent for zone configuration group 1 alarm reports. The desired event code
should be chosen from the Contact I.D Configuration Group Event Table in the Appendix section.
FEATURE 68 CONFIGURATION GROUP 1 CHARACTERISTIC SELECT
SEGMENT 1
1
Fire (turn on if this is a fire zone)
2
24 hour (turn on for non-fire 24 hour zones)
3
Key-switch zone (normally open switch)
4
Follower (turn on for burglary zones that are Instant during non-entry times)
(5)
Delay 1 zone (follows timer 1 entry and exit times)
6
Delay 2 zone (follows timer 2 entry and exit times)
7
RESERVED
8
Local only (turn on if this zone should not be reported)
SEGMENT 2
1
On if configuration group will beep the code pad for alarm
(2)
On if configuration group will sound the yelping siren for alarm
3
On if configuration group will sound the steady siren for alarm
4
On if configuration group will chime
(5)
On if configuration group can be bypassed
6
On if configuration group is included in the Group Bypass
(7)
On if configuration group is Force Arm
(8)
On if configuration group is Active in Partial Mode
SEGMENT 3
1
On enables Fast Loop Response. (50mS)- off = 500mS
(2)
On enables Double End Of Line Tamper zone
3
On enables Trouble Reporting zone. (Day zone and Fire zones)
4
On if configuration group is a Twin Trip Zone
(5)
On enables Dialer Delay zone
(6)
On if configuration group will siren / communicator attempt count
(7)
On enables Restore reporting
(8)
On enables Listen-In
FEATURE 69 CONFIGURATION GROUP 2 ALARM EVENT CODE
SEGMENT 1
3
Feature 69 contains the Contact I.D event code sent for zone configuration group 2 alarm reports. The desired event code should be chosen
from the Contact I.D Configuration Group Event Table in the Appendix section.
FEATURE 70 CONFIGURATION GROUP 2 CHARACTERISTIC SELECT
SEGMENT 1
5 SEGMENT 2 2457 SEGMENT 3 25678
Use "Configuration Group Characteristic table" described in Feature 68, of this section.
FEATURE 71 CONFIGURATION GROUP 3 ALARM EVENT CODE
SEGMENT 1
3
Feature 71 contains the Contact I.D event code sent for zone configuration group 3 alarm reports. The desired event code should be chosen
from the Contact I.D Configuration Group Event Table in the Appendix section.
FEATURE 72 CONFIGURATION GROUP 3 CHARACTERISTIC SELECT
SEGMENT 1
5 SEGMENT 2 24578 SEGMENT 3 25678
Use "Configuration Group Characteristic table" described in Feature 68, of this section.