Installation manual

3
MAIN OPTIONS
Areas -
The NX-16 can have up to a maximum of eight separate systems (Areas) with distinct reporting codes, user codes, and
operating options for each system. (See Features 16-21 and 37-58)
Arm / Disarm Codes -
The NX-16 can have 99 four-digit codes or 66 six-digit codes to arm/disarm the control. All codes must have the same number
of digits. User codes are programmed and viewed from the code pad functions [*] 5 and [*] 6. The factory default for User #1 is
[1]-[2]-[3]-[4] when using a 4-digit code, or [1]-[2]-[3]-[4]-[5]-[6] for a 6-digit code. This code can then be used to enter the new
arm/disarm codes. (See Feature 0)
Auto Arm in Partial -
The NX-16 can be armed automatically in the partial mode. This option can only be used for area one. If Auto Arm in Partial is
enabled, area one cannot have full mode Auto Arming selected. (See Feature 22)
Automatic Arming -
If programmed, the NX-16 will Auto Arm at a specified time. At this time, the code pad will beep for 50 seconds before the panel
arms. The auto arming process can be stopped by a valid code entry. The Auto Arming of an area can be programmed to be
silent. If closing reports are sent, the user code will be 97. (See Features 16, and 33-36)
Auxiliary Outputs -
The NX-16 has two programmable relay outputs that can be used to activate a strobe and two internal sirens. (See the terminal
description Features 26-29)
Auxiliary Power Over current -
The NX-16 will illuminate the "Service" LED on the code pad whenever too much current is drawn from any device powered by
the system. This condition can be reported to the central station. (See Features 9 and 22)
Box Tamper-
The NX-16 has an input for a normally closed tamper switch (see terminal drawing). The Box Tamper can be programmed to
report and/or sound the siren and/or the Code Pad. These terminals can be enabled or disabled in programming. (See
Features 22 and 23)
Code Pad Zone Start -
The NX-16 LED Code Pads can be programmed with a start zone form 1 to 48. The starting zone programmed into the LED
Code Pad via function [*] [9][2] will tie the system zone to zone one (1) of the Code Pad. I.E. If you wish to start displaying zone
25 as the zone one (1) on a LED Code Pad, program a 25 as the start zone into the Code Pad that will function in this manner.
When system zone 25 is faulted, zone LED one (1) will illuminate on the programmed Code Pads. Zone bypasses will be tied to
the Code Pad LED number, however reporting will follow the system zone number.
Configuration Groups-
The NX-16 has 20 programmable and 10 fixed zone configuration groups that determine how each zone will function and report.
The first 20 groups can be user definable.
Dual End of Line -
All NX-16 zones can be enabled for Tamper monitoring if the Dual End of Line option is enabled. Zone Doubling cannot be used
if the option is enabled. (See Feature 22)
Dynamic Battery Test -
The NX-16 can be programmed to perform a Dynamic Battery Test for a selected duration the first time the panel is armed or
disarmed every day. The NX-16 can also be programmed to perform a missing battery test every 12 seconds. (See Features 22
and 25)