Installation manual

28
FEATURE 31 AUXILIARY OUTPUT 4 - EVENT AND TIME
SEGMENTS 1-2
OUTPUT EVENT - 21 OUTPUT TIME - 0
Feature 31 sets the output event and output active time for auxiliary output four (4). Use the chart in this section to
select the event in segment 1, that will activate Auxiliary Output 4. Program the timing in segment 2, from 0-255
(minutes or seconds, depending on data programmed in Segment 1, Feature 27). Programming a "0" makes the
output follow the event.
AUXILIARY OUTPUT EVENT SELECTION
DATA EVENT DATA EVENT
0 Burglary Alarm 26 Fire Trouble
1 Fire Alarm 27 Chime
2 24 Hour Alarm 28 Expander Trouble
3 Trouble Alarm 29 Dynamic Battery Test Time
4 Tamper Alarm 30 Open Period
5 Yelping Siren 31 Closed Period
6 Steady Siren 32 Listen-In
7 Any Siren 33 Line Seizure
8 Any Bypass 34 Reserved
9 AC Fail 35 Fail To Communicate
10 Low Battery 36 Telephone Line Fault
11 Duress 37 Program Mode
12 Aux 1 Code Pad Zone 38 Download In Process
13 Aux 2 Code Pad Zone 39 Reserved
14 Panic Code Pad Zone 40 Short Circuit
15 Code Pad Tamper 41 Box Tamper
16 Auto-test 42 Siren Tamper
17 Alarm Memory 43 Any Open
18 Entry 44 Any Short
19 Exit 45 Any Fault (Open/ Short on Non-Fire Zone)
20 Entry or Exit 46 Any Alarm
21 Armed State 47 Beeping Code pad
22 Disarmed State 48 Code Entry (See note below)
23 Ready 49 ITI Keyfob Light Key (function 1)
24 Not Ready 50 ITI Keyfob * Key (function 2)
25 Fire 51 Strobe
Note : When event 48 is programmed, it is possible to program a user code's authorization to select which
output(s) a particular code will activate. When LED 8 is on for an authorization, then LEDs 1- 4 correspond to that