Installation manual
27
FEATURE 26 AUXILIARY OUTPUT 1-4 AREA SELECTION
Feature 26 is used to select which area(s) the events must occur in before the output will activate. Feature 26 has
4 segments. Segment 1 corresponds to output 1, and Segment 4 corresponds to output 4.
AREA 1 AREA 2 AREA 3 AREA 4 AREA 5 AREA 6 AREA 7 AREA 8
SEGMENT 1 – OUTPUT 1
(1) (2) (3) (4) (5) (6) (7) (8)
SEGMENT 2 – OUTPUT 2
(1) (2) (3) (4) (5) (6) (7) (8)
SEGMENT 3 – OUTPUT 3 (1) (2) (3) (4) (5) (6) (7) (8)
SEGMENT 4 – OUTPUT 4 (1) (2) (3) (4) (5) (6) (7) (8)
FEATURE 27 AUXILIARY OUTPUT 1-4 SPECIAL TIMING
Feature 27 contains special timing option activation for the four auxiliary outputs. Segment 1 corresponds to output
1, Segment 4 corresponds to output 4.
SEGMENTS 1 – 4
OUTPUTS 1 - 4
1 On if output should be timed in minutes; Off if timed in seconds
2
On if output should latch; Off if output should be timed
(3)
On if output should stop timing upon code entry; Off if the output should follow timer
4
On if output should only activate between the closing and opening time in Features 33 and 34
5
On if output should only activate between the opening and closing time in Features 33 and 34
6
On if output should be inverted (0 volts going to 12 volts when activated)
7
RESERVED
8
RESERVED
FEATURE 28 AUXILIARY OUTPUT 1 - EVENT AND TIME
SEGMENTS 1-2
OUTPUT EVENT - 51 OUTPUT TIME - 0
Feature 28 sets the output event and output active time for auxiliary output one (1). Use the chart in this section to
select the event in segment 1, that will activate Auxiliary Output 1. Program the timing in segment 2, from 0-255
(minutes or seconds, depending on data programmed in Segment 1, Feature 27). Programming a "0" makes the
output follow the event.
FEATURE 29 AUXILIARY OUTPUT 2 - EVENT AND TIME
SEGMENTS 1-2
OUTPUT EVENT - 7 OUTPUT TIME - 0
Feature 29 sets the output event and output active time for auxiliary output two (2). Use the chart in this section to
select the event in segment 1, that will activate Auxiliary Output 2. Program the timing in segment 2, from 0-255
(minutes or seconds, depending on data programmed in Segment 1, Feature 27). Programming a "0" makes the
output follow the event.
FEATURE 30 AUXILIARY OUTPUT 3 - EVENT AND TIME
SEGMENTS 1-2
OUTPUT EVENT - 23 OUTPUT TIME - 0
Feature 30 sets the output event and output active time for auxiliary output three (3). Use the chart in this section
to select the event in segment 1, that will activate Auxiliary Output 3. Program the timing in segment 2, from 0-255
(minutes or seconds, depending on data programmed in Segment 1, Feature 27). Programming a "0" makes the
output follow the event.