Installation manual
26
FEATURE 25 SYSTEM TIMERS
Feature 25 contains the duration of various system timing functions. Example: If you desire the duration of the
Strobe time to be 48 hours, you should program [4] [8] [r] in segment 2 of this feature. The [4] [8] is the number of
hours, and the [r] stores the data and moves to the next segment of this feature.
SEGMENTS 1-10 30 0 2 30 5 5 3 0 120 0
SEGMENT 1
Partial Arm Entry Time (0 - 255 SEC)
SEGMENT 2
Strobe Time (0 - 255 HOURS).
SEGMENT 3
Dynamic Battery Test Duration (0 – 255 MIN).
SEGMENT 4
AC Failure Report Delay (0 -255 MIN).
SEGMENT 5
Siren Time (1 - 255 MIN).
SEGMENT 6
Twin Trip Time (0 - 255 MIN).
SEGMENT 7
Chime Time in 50 ms increments (0 - 255).
SEGMENT 8
Dialer Delay Time (0 - 255 SEC)
SEGMENT 9
Fire Alarm Verification Time (120 – 255 SEC)
SEGMENT 10
Listen - In Time (0 - 255 SEC)
SYSTEM TIMER OPTIONS TABLE
Partial Arm Entry Time
The Partial Arm Entry time is the delay time that will be allocated to all active zones in Partial Arm Mode. Fire and 24 hour zone
will not be affected in Partial Arm Mode. The valid time selection in this segment is 0 to 255 seconds.
Strobe Time
The Strobe time is the duration that output programmed to follow the strobe time will activate. The valid time selection in this
segment is 0 to 255 hours, where “0” = Latching.
Dynamic Battery Test
The NX-16 can perform a Dynamic Battery Test for the duration in this segment at the disarming of the first area after 0:00
hours once each 24 hour cycle. This option is enabled by programming a test duration in this segment. The valid time
selection in this segment is 0 to 255 minutes, where “0” = disable.
AC Fail Report
The number programmed in this segment represents the number of 1 minute increments the AC power is lost before a
communication is initiated, from 1 to 255 minutes. The AC power restore will also delay reporting until after the number of
minutes programmed in this feature has elapsed.
Siren Time
The Siren Time is the duration that the siren output and auxiliary outputs programmed to follow the siren time will activate. The
valid time selection in this segment is 1 to 255 minutes.
Twin Trip Time
This segment contains the number of one (1) minute increments in the Twin Trip Zone Time Period. The Twin Trip Zone Time
Period can be programmed in one (1) minute increments from 1 to 255. The time programmed in this feature will set the time
period whereby two or more zones must trip before an alarm condition will be registered or the one zone must trigger twice
within this time period, or a continues trip longer exceeding 10 seconds.
Chime Time
The NX-16 code pad Chime is a true chime sound, which can be set to chime once, follow the input status or latch until a valid
code is entered. The duration options programmable in this segment are:-
“0” = Follow, “3” = Chime once or “255” = Latch.
Dialer Delay Time
The NX-16 can delay the dialing of all non (24) hour zones by the duration programmed in this feature. This option can be used
as a false alarm reduction method. The valid time selection in this segment is 0 to 255 seconds.
Fire Alarm Verification Time
When enabled, the NX-16 will verify a Fire alarm by requiring more than one trip on a smoke detector within the time
programmed in this segment before creating an alarm. The valid time selection in this segment is 120 to 255 seconds.
Listen - In Time
This option is not currently supported.