Installation manual
25
SYSTEM OPTIONS TABLE
First To Open / Last To Close
If enabled, the NX-16 will only send a closing report when the last area is armed. NOTE: the last area to arm must have
open/close reports enabled. The NX-16 will only send an opening report when the first area is disarmed. NOTE: The first area
to disarm must have open/close reports enabled.
Force Arm Bypass Reports
If enabled, the NX-16 restricts bypass reports when zones are forced armed. Otherwise, when a zone is forced armed (and
bypass reports are enabled), bypass reports are sent at the end of exit time. If forced armed zones re-seal during the armed
period, bypass restores are sent.
Limited Sirens / Communicator
If enabled, the NX-16 will only set one siren activation per zone and/or one alarm report per zone. This option must be disabled
if the siren and communicator attempt counter option is used. If limited communicator is enabled, restore reports (if enabled)
will be sent at disarm, otherwise restore reports will be sent as they occur.
Lost Clock
If enabled, the NX-16 will illuminate the service LED whenever the internal clock is interrupted.
On-Board Zone Disable
If enabled, the NX-16 can disable the 8 on-board zone. This is used when the NX-16 is used as a totally wireless system.
Radio Remote Arm
If enabled, the NX-16 will activate the sirens every time the system is armed or disarmed with a key-switch zone or integrated
wireless keyfob. The sirens will chirp once for arming and twice for disarming. The strobe will flash for 3 seconds for arming
and 6 seconds for disarming.
Silent Exit Option
The exit delay can be silenced by pressing [r]-[Exit] before arming the control panel, or when using the re-exit option. The exit
delay can also be silenced permanently in all partitions.
Tamper Siren
If enabled, all zone tampers and module tampers will set the system sirens.
Telephone Line Cut Siren
If enabled, it will set the siren for the siren time when ever the phone line monitor is activated. The phone line siren can be
reset to be the entry of a valid code. The options set phone line cut sirens in either armed and or disarmed mode. In a multi-
area system, “a system armed state” would be represented by any area that is armed.
Voltage Output
If enabled, the on-board siren output will become a 1 AMP 12V DC output to drive 12V sirens.
Zone Doubling
If enabled, the 8 on-board zones will be doubled to 16 zones. Zone 1 will represent zones 1 and 9, and zone 8 will represent
zone 8 and 16. This option cannot be selected for zones other than the 8 zones on the main panel. This option cannot be used
in conjunction with the DEOL option. To disable this option, first de-select it, and then power down the system.