FEATURE 22 SYSTEM OPTIONS
Feature 22 is used to enable various system option and reporting options.
SEGMENT 1
(1) On if siren sounds for "Telephone Line Cut" when armed
2
On if siren sounds for "Telephone Line Cut" when disarmed
3
On if siren blast at arming – ( A siren chirp when any area is armed.)
4
On if siren blast at exit expiration - ( A siren chirp when any area exit delay expires.)
5
On if siren blast at closing kiss-off - ( A siren chirp when any area sends a closing report.)
(6)
On if siren limited to once per zone
7
On if siren sounds for a Zone or Box Tamper
(8)
On if siren blasts 1 time for key-switch and wireless arming; 2 times for disarming
SEGMENT 2
1
On if siren driver should be a voltage output. Off if on board siren driver enabled
2
On if sirens should sound on expander trouble
3
On if Communicator limited to once per zone
4
On if First to Open Last to Close Reports
5
On if Battery Missing Test is performed every 12 seconds
(6)
On if Strobe flashes for 3 seconds for Key-switch Arming and 6 seconds for disarming
7
On if Manual Communicator Test performed during [r]- [44] test function
(8)
On if Box Tamper Pins on the control panel are enabled
SEGMENT 3
(1)
On if Box Tamper report enabled
(2)
On if AC Fail reporting enabled
(3)
On if Low Battery reporting enabled
(4)
On if Aux. Power Over-current report enabled
(5)
On if Siren Supervision report enabled
(6)
On if Telephone Line Cut report enabled
7
RESERVED
(8)
On if Expander Trouble reporting enabled
SEGMENT 4
(1)
On if Fail To Communicate report enabled
(2)
On if Log Full report enabled
(3)
On if Auto-test report enabled
(4)
On if Start/End programming report enabled
(5)
On if End Download report enabled
(6)
On if Sensor Low Battery report enabled
(7)
On if Sensor Missing report enabled
8
On if Expanded Contact I.D report enabled
SEGMENT 5
(1)
On enable Lost Clock service light
2
On enables Zone Doubling
3
On disables all hardwired zones on the NX-16
4
On will enable all Dual End of Line resistors on all zones (DEOL)
5
On will not allow zones that are force armed to report bypass
6
On enables Silent Exit option
7
On will disable 50 Hz synchronization
8
On will Auto Partial Arm Area 1