DATA DEFAULT ZONE CONFIGURATION ZONE
"14"
HANDOVER: Partial - Twin Trip - Group Isolate - Forced Arming - Interior zone that follows the entry
delay zones. Instant alarm type unless an entry zone if faulted first. This zone will be active in partial
mode. This zone type may be faulted while arming if forced arming is enabled in the area options. This
zone type will require two triggers or another zone would have to have been trigged before it will activate
an alarm. This zone type will be part of the group bypass zones.
"15"
INSTANT: - Produces an instant alarm if tripped when armed. Ignored when disarmed. This zone will be
bypassed in partial mode.
"16"
INSTANT: Partial - Produces an instant alarm if tripped when armed. Ignored when disarmed. This
zone will be active in partial mode.
"17"
INSTANT: Partial (NO DEOL) - Produces an instant alarm if tripped when armed. Ignored when
disarmed. This zone will be active in partial mode. This zone type will not be enabled for dual end of line
monitoring if enabled in the system options.
"18"
INSTANT: Twin Trip - Forced Arming - Produces an instant alarm if tripped when armed. Ignored when
disarmed. This zone will be bypassed in partial mode. This zone type may be faulted while arming if
forced arming is enabled in the area options. This zone type will require two triggers or another zone
would have to have been trigged before it will activate an alarm.
"19"
INSTANT: Group Bypass - Produces an instant alarm if tripped when armed. Ignored when disarmed.
This zone will be bypassed in partial mode. This zone type will be part of the group bypass zones.
"20"
INSTANT: Partial – Chime - Produces an instant alarm if tripped when armed. Ignored when disarmed.
This zone will be active in partial mode. This zone type will set the code pad chime if set via the code pad
[Chime] key.
"21"
INSTANT: Partial - Twin Trip - Produces an instant alarm if tripped when armed. Ignored when
disarmed. This zone will be bypassed in partial mode. This zone type will require two triggers or another
zone would have to have been trigged before it will activate an alarm.
"22"
INSTANT: Partial - Group Bypass - Produces an instant alarm if tripped when armed. Ignored when
disarmed. This zone will be active in partial mode. This zone type will be part of the group bypass zones.
"23"
INSTANT: Twin Trip - Group Bypass - Produces an instant alarm if tripped when armed. Ignored when
disarmed. This zone will be bypassed in partial mode. This zone type will require two triggers or another
zone would have to have been trigged before it will activate an alarm. This zone type will be part of the
group bypass zones.
"24"
INSTANT: Partial - Twin Trip - Group Bypass - Produces an instant alarm if tripped when armed.
Ignored when disarmed. This zone will be active in partial mode. This zone type will require two triggers
or another zone would have to have been trigged before it will activate an alarm. This zone type will be
part of the group bypass zones.
"25"
INSTANT: Local - Produces an instant alarm if tripped when armed. Ignored when disarmed. This zone
will be bypassed in partial mode. This zone will to activate to communicator.
"26"
24 HOUR: Audible - A trip on a 24 Hour zone produces an instant alarm when armed or disarmed. This
zone type will set sirens.
"27"
24 HOUR: Silent - A trip on a 24 Hour zone produces an instant alarm when armed or disarmed. This
zone type will not set sirens.
"28"
FIRE: - A short on a FIRE zone will create an alarm condition when the system is armed or disarmed. An
open will create a Trouble condition. The code pad zone LED is steady for a fire condition and flashing
for a trouble condition. After a fire activation the * [7] function must be pressed on the code pad to clear
the condition and reset the fire zone.
"29"
DAY ZONE: – When armed, a trip produces an instant alarm. When disarmed, a trip activates the code
pad sounder.
"30"
KEY-SWITCH: - A zone attached to a momentary key switch will cause the NX-16 to arm or disarm when
the zone is momentarily shorted from a sealed condition I.E. a 3.3K resister must be used to seal the
zone for the option to work. Note. If dual end of line monitoring is enabled in system options, this zone
type must have its EOL configuration as all other DEOL zones. I.E. Two 3.3K resistors must be used,
which allow full line monitoring for this zone type.