Installation manual

21
DEFAULT ZONE CONFIGURATIONS TABLE
Zones can be programmed to be one of thirty different zone configurations (Zone Types). Configurations 1 to 20
can be modified in the configuration group section of this manual. Configuration groups 21 to 30 are factory set
and cannot be altered. Choose one of the 30 default zone configurations to program into each of the zone
configuration segments in Features 18, 20 59 61 63 and 65. Study this table for the appropriate zone configuration
group for each zone.
DATA DEFAULT ZONE CONFIGURATION TABLE
"1"
ENTRY / EXIT DELAY 1: Partial - Forced Arming – A trip will start entry delay 1. This zone will be
active in partial mode. This zone type may be faulted while arming if forced arming is enabled in the area
options.
"2"
ENTRY / EXIT DELAY 1: Chime - Forced Arming – A trip will start entry delay 1. This zone will be
bypassed in partial mode. This zone type will set the code pad chime if set via the code pad [Chime] key.
"3"
ENTRY / EXIT DELAY 1: Partial - Chime - Forced Arming – A trip will start entry delay 1. This zone will
be active in partial mode. This zone type may be faulted while arming if forced arming is enabled in the
area options. This zone type will set the code pad chime if set via the code pad [Chime] key.
"4"
ENTRY / EXIT DELAY 2: Partial - Forced Arming A trip will start entry delay 2. This zone will be
active in partial mode. This zone type may be faulted while arming if forced arming is enabled in the area
options.
"5"
ENTRY / EXIT DELAY 2: Partial - Chime - Forced Arming - A trip will start entry delay 2. This zone will
be active in partial mode. This zone type may be faulted while arming if forced arming is enabled in the
area options. This zone type will set the code pad chime if set via the code pad [Chime] key.
"6"
HANDOVER: Forced Arming - Interior zone that follows the entry delay zones. Instant alarm type
unless an entry zone if faulted first. This zone will be bypassed in partial mode. This zone type may be
faulted while arming if forced arming is enabled in the area options.
"7"
HANDOVER: Partial - Forced Arming - Interior zone that follows the entry delay zones. Instant alarm
type unless an entry zone if faulted first. This zone will be active in partial mode. This zone type may be
faulted while arming if forced arming is enabled in the area options.
"8"
HANDOVER: Twin Trip - Forced Arming - Interior zone that follows the entry delay zones. Instant
alarm type unless an entry zone if faulted first. This zone will be bypassed in partial mode. This zone
type may be faulted while arming if forced arming is enabled in the area options. This zone type will
require two triggers or another zone would have to have been trigged before it will activate an alarm.
"9"
HANDOVER: Group Isolate - Forced Arming - Interior zone that follows the entry delay zones. Instant
alarm type unless an entry zone if faulted first. This zone will be bypassed in partial mode. This zone
type may be faulted while arming if forced arming is enabled in the area options. This zone type will be
part of the group bypass zones.
"10"
HANDOVER: Twin Trip - Chime - Forced Arming - Interior zone that follows the entry delay zones.
Instant alarm type unless an entry zone if faulted first. This zone will be bypassed in partial mode. This
zone type may be faulted while arming if forced arming is enabled in the area options. This zone type will
require two triggers or another zone would have to have been trigged before it will activate an alarm. This
zone type will set the code pad chime if set via the code pad [Chime] key.
"11"
HANDOVER: Partial - Twin Trip - Forced Arming - Interior zone that follows the entry delay zones.
Instant alarm type unless an entry zone if faulted first. This zone will be active in partial mode. This zone
type may be faulted while arming if forced arming is enabled in the area options. This zone type will
require two triggers or another zone would have to have been trigged before it will activate an alarm.
"12"
HANDOVER: Partial - Group Bypass - Forced Arming - Interior zone that follows the entry delay
zones. Instant alarm type unless an entry zone if faulted first. This zone will be active in partial mode.
This zone type may be faulted while arming if forced arming is enabled in the area options. This zone
type will be part of the group bypass zones.
"13"
HANDOVER: Twin Trip - Group Bypass - Forced Arming - Interior zone that follows the entry delay
zones. Instant alarm type unless an entry zone if faulted first. This zone will be bypassed in partial mode.
This zone type may be faulted while arming if forced arming is enabled in the area options. This zone
type will require two triggers or another zone would have to have been trigged before it will activate an
alarm. This zone type will be part of the group bypass zones.