AREA OPTIONS TABLE
Code Pad Tamper
If enabled, the NX-16 will disable the Code Pad for 60 seconds and communicate a tamper signal to the central station if 30
key-presses are entered without producing a valid code. The Code Pad sounder will remain functional.
Exit Error
If enabled, the NX-16 will send an "Exit Error Report" if an entry/exit zone is faulted at the instant the exit delay expires. This
report will be sent along with the user number that armed the system, if the panel is not disarmed before the entry delay
expires. The alarm report will also be sent. Even if this option is not enabled, the siren will sound if any entry/exit zone is
faulted at the instant the exit delay expires. This option is enabled by default, but needs to be set to report in Feature 9 for
proper operations.
Force Arming
When enabled, the NX-16 can be Force Armed with zones violated. Under this condition, if a force arm zone is not secure, the
"Ready" LED will flash. At the end of the exit delay, these zones will become bypassed. If these zones become secured any
time during the arming cycle, they will be un-bypassed and active in the system. If "Bypass Report" is enabled, the force
arming zones can be programmed to report bypass when they are Force Armed (default), or to not report bypass even if
"Bypass Report" is enabled (refer to system options).
Group Bypass
A designated group of zones can be programmed to bypass by pressing [Bypass]- [0]-[0]- [Bypass] prior to arming.
Group Toggle
If enabled, the NX-16 can toggle the Group Bypass zone in and out of bypass mode by pressing the [Bypass] key. This option
if active when ever the NX-16 is in either Partial or Full arm mode.
LED Extinguish
This option will extinguish all LED๎s on the Code Pad, except the "Power" LED, after 60 seconds without a key-press. Pressing
any numeric key will illuminate all LED๎s.
Partial Mode
This unique arming mode has been developed to reduce the most common source of false alarms. When armed in the "Partial"
mode, the opening of any zones designated as "Partial Mode Zone" will initiate the Code Pad sounder and start the Partial
Mode entry delay before creating an alarm. All other zones will be bypassed during Partial mode. To arm this area in Partial
Mode, press the [Partial] key on the code pad. This arming mode will encourage system owners to use their system more
frequently when the premise is occupied.
Partial Mode Security
If enabled the NX-16 will require a full code to disarm it from the Partial Mode.
Quick Arm Option
The NX-16 has a one button "Quick Arm" option which can be used to arm the system by pressing the [ON] key on the Code
Pad. If closing reports are sent, the user code will be 98.
Recent Closing
If enabled, the NX-16 will send a "Recent Closing Report" to the central station if an alarm occurs within 5 minutes after the
panel is armed. The user number that armed the system will also be sent. This option is enabled by default, but needs to be
set to report in Feature 9 for proper operations.
Re-exit
The NX-16 has the ability to restart the exit delay if required without disarming the system by pressing the [Exit] key while the
system is running the exit delay. This option can only be used once per arming cycle.
Silent Automatic Arming
If enabled, the NX-16 will Auto Arming this area and not set the 50 seconds code pad sounder on. This option is used when
you donโt want to alert any other area of your Auto Arm time.
Universal Arming (Uni Arm)
When enabled, using the quick arm function or entering a valid user code can automatically arm in the NX-16 in the preset
Partial mode if an exit zone fault is not detected during the exit delay time.
Zone Bypassed Sounder Alert
If this option is enabled, the NX-16 will beep the Code Pad sounder upon arming if a zone is bypassed.