Installation manual

17
FEATURE 12 DOWNLOAD ACCESS CODE
SEGMENTS 1-8
1 6 0 0 0 0 0 0
Feature 12 contains the eight digit access code the NX-16 must receive from the downloading software before the
panel will permit downloading to occur.
FEATURE 13 NUMBER OF RINGS (SEG 1) / NUMBER OF CALLS TO ANSWER (SEG 2)
SEGMENTS 1-2
0 0
Feature 13, segment 1 contains the number of rings the NX-16 must detect before answering the telephone line
when initiating a download session. A value of 1 to 15 can be entered in this segment. Segment 2 contains the
number of calls the NX-16 must detect before accepting the number of rings in segment 1. A value of 1 to 15 can
be entered in this segment. A call is satisfied by one (1) or more rings, and then an eight (8) second period of no
ring. The next call must then be made within 45 seconds. The total number of calls must be reached before the
NX-16 will count for the number of rings (in segment 1) during the necessary subsequent call . A “0” = disabled.
FEATURE 14 DOWNLOAD CONTROL
Feature 14 contains the option selections for the controlling of download sessions. The following options can be
enabled or disabled using this feature.
SEGMENT 1
1
On enables two call answering machine defeat. (see “Option Definitions” for a full explanation of
this option).
2
RESERVED
3
On requires call back before download session. (Refer to Feature 15).
4
On enables Control Panel Shutdown. (Can only be viewed from the code pad, must be
changed through downloading).
5
On locks all local programming. (Can only be viewed from the code pad, must be changed
through downloading).
6
On locks programming of all features associated with the communicator. (Can only be viewed
from the code pad, must be changed through downloading).
7
On locks out download section. (If "On", Features 12-15 cannot be viewed from the code pad.
Note: This segment can only be changed through the download software.
8
On enables call back at auto test interval to perform download software automatic functions.
(Refer to your download software help for a full explanation of this option).
FEATURE 15 CALL BACK NUMBER
SEGMENTS 1-20
14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14
If a telephone number is programmed into this feature, and "Require Callback" is enabled in feature 14, the control
panel will hang up for approximately 10 seconds and then call back. If pulse dialing is desired, program an "15" in
the segment where pulse dialing should begin. If the entire number should be pulse dialing, program a “15" in the
first segment. Four-second delays can be obtained anywhere in the sequence by programming a "13" in the
appropriate delay feature. WARNING: THE CALLBACK PHONE NUMBER SHOULD ALWAYS BE REVIEWED
FOR ACCURACY BEFORE DISCONNECTING.