PROGRAMMING THE NX-16 CONTROL
NUMERICAL DATA: Numerical data is programmed by entering a number from 0-255 on the numeric keys of the
system code pad. To view the data in a feature, a binary process is used. With this process, the LED’s for zones 1
through 8 are utilized, and the numeric equivalents of their illuminated LED’s are added together to determine the
data in a programming feature. The numeric equivalents of these LED’s are as follows:
Zone 1 LED = 1 Zone 2 LED = 2 Zone 3 LED = 4 Zone 4 LED = 8
Zone 5 LED = 16 Zone 6 LED = 32 Zone 7 LED = 64 Zone 8 LED = 128
Example: If the numerical data to be programmed in a feature is "66", press [6]-[6] on the code pad. The LED’s for
Zone 2 and Zone 7 will become illuminated indicating 66 is in that feature (2 + 64 = 66). See this example on page
10.
Once the data is programmed, press the [r] key to enter the data and advance to the next segment of that feature.
After the last segment of a feature is programmed, pressing the [r] key will exit that feature, turn the "Ready" LED
off and the "Armed" LED on. As before, you are now ready to enter another programming feature. If an attempt is
made to program a number too large for a particular segment, the code pad sounder will emit a triple beep,
indicating an error, and remain in that segment awaiting a valid entry.
OPTION SELECTION DATA: Option selection data will display the current condition (on or off) of eight options
associated with the programming feature and segment selected. Pressing a button on the touch-pad (1 thru 8) that
corresponds to the "option number" within a segment, will toggle (on/off) that option. Pressing any numeric key
between [1] and [8] for selection of a option, will make the corresponding LED illuminate (option ON). Press the
number again, and the LED will extinguish (option OFF). You will see that numerous options can be selected from
within one segment. For instance, if all eight options of a segment are desired, pressing [1]-[2]-[3]-[4]-[5]-[6]-[7]-[8]
will turn on LED's 1 thru 8 as you press the keys, indicating that those options are enabled. After the desired setting
of options is selected for this segment, press the [r] key. This will enter the data and automatically advance to the
next segment of the feature. When you are in the last segment of a feature and press the [r] to enter the data, you
will exit that feature. This will now turn the "Ready" LED off and the "Armed" LED on. As before, you are now
ready to enter another programming feature.
LOADING FACTORY DEFAULTS: There are two ways to load the factory defaults. The first is to enter the
program mode using the procedure on page 9, then type [9]-[1]-[0]-[#]. The code pad will beep 3 times indicating
that the loading is in progress. The loading takes about 6 seconds. The second is to type [9][7][1][3][0][0] within 10
seconds of power up at any code pad, which is not programmed for master mode. The procedure will default the
NX-16 even if it is armed.
ENROLLING MODULES AND CODE PADS : For supervision purposes, the NX-16 has the ability to automatically
find and store in its memory, the presence of all code pads, zone expanders, wireless receivers, and any other
module connected to the data terminal whenever exiting the program mode. The enrolling process takes about 12
seconds, during which time the "Service" LED will illuminate. Once a module is enrolled, if it is not detected by the
control, the "Service" LED will illuminate.