User's Manual

Model Name:
UG0B Product Name : Keyboard
CYCLES/SEC 4 4
JUDGMENT
After life test:
1. No functional defect.
2. Key shall have to be lifted up successfully.
NOTE
1. 18 keys per keyboard shall be tested with probe placed in the center of keys
except for Spacebar
Main keyboard area - 10M cycle
- Spacebar (probe at right edge) - Alt Right - Shift Right - Search
- backspace - Ctrl Left - a - 4
- t - j - / - Enter
-^
FLW row- 5M total cycle
- ESC (#1) - Back (#2) - Forward (#3) - Power (#12) - Left Arrow
2. 4pc keyboards test life cycle.
3. Keys shall be tested at a rate of 4 cycles/second and force displacement data
recorded at 0, 500k, 1M, 3M, 5M, 7M, 10M cycles for main keyboard area; data
recorded at 0, 500k, 1M, 3M, 5M cycles for the FLW area
3.5.8KeycapPullOutForce:
(1) Normal keys : 800 g min. pulling force applied opposite to the direction of keyboard
operation.
(2) Small keys : 700 g min. pulling force applied opposite to the direction of keyboard
operation.