Owner's manual

24
Symptom
Using ON/OFF switch does not work
Machine won’t power up
Cause
No power at outlet
Make sure power cord is plugged in to
machine and outlet
Release e-stop (230v machine only)
E-stop nut is loose and stuck down in the
off position (230v machine only)
On/off switch needs to be replaced
Wiring lead disconnected
Symptom
Tip of drills burn or discolor
Cause
Wheel needs to be cleaned
Material take off too aggressive
Wheel needs to be replaced
Grinding wheel obstructed and can’t rotate
Grinding motor bad
Symptom
Unable to secure drill in or release drill
from chuck
Cause
Tapered shank drill
The drill may have a slight taper to the
body
Shank of drill larger than body
Drill has multiple diameters that are
interferi
ng with jaws
Incorrect drill diameter for that particular
ch
uck
Drill flutes are damaged or have burrs
Chuck needs to be cleaned
Symptom
Drill incorrectly split
Cause
Check settings on the split point fixture
Did not align correctly
Point Split Tube calibration is off
Symptom
Material take off varies
Cause
Wheel not secure to motor hub
Wheel calibration is off after new wheel
change
Cam dog not properly seated in alignment
slot during alignment set up
Drill is pushing back in the chuck during
grinding
Operator is not sparking drill out
Symptom
No material take off during grinding
Cause
Drill loose in chuck
Drill tip not touching the pusher shaft cap
during alignment process
Symptom
Length of time drill is in the grind becomes
excessive
Cause
Material take off too excessive
Grinding wheel needs to be cleaned
Grinding wheel needs to be replaced
Symptom
Lip h
eight concentricity is out of tolerance
Cause
Material take off too excessive
Chuck needs to be cleaned
Sharpening tube needs to be cleaned
Chuck is worn out and needs to be
replaced
Sharpening tube is worn and needs to be
replaced
Wheel is not running true
Trouble Shooting XT-3000 Drill Sharpening