Instructions User guide

65
Symptom
Failed Initialization screen test
Cause
Axis driver card failure
Limit sensors bad
Solenoid bad
Machine has moved past the limit switches
Symptom
LCD screen too light or dark to read
Cause
Contrast needs adjusted Refer to page 32
LCD back light failure
LCD bad
Symptom
LCD screen displays garbage or grossly
inaccurate information.
Cause
Machine temperature is too cold/hot – do
not operate until machine temperature
reaches above 7°C (45°F) but not more
than 32°C (90° F)
Restore calibrations from locked area
LCD battery is dead
LCD is bad
Symptom
After pressing “Cycle Start” the machine
does not move into the sharpening cycle
Cause
Make sure drill has been loaded properly
and sensor button has been depressed
Close door
Software has caused machine to hang up –
turn machine off and then on again
Cycle start switch needs replacement
Printed circuit board on
back of LCD is bad
Symptom
Drill rotates in front of fiber optic sensor
failing to locate cutting edge
Cause
Old software installed
Drill diameter is smaller than 3mm
Drill diameter is of a smaller dimension
with a thick web
Color of drill is interfering with cutting
edge detection – typically gold or black
drills Refer to page 61
False diameter was input or detected in
Fiberoptic Amplifier Baseline setting has
changed. Contact Darex for instructions.
manual mode
Cutting edge is broken
Cutting edge has shinny build up, such as
aluminum
Surface finish too rough
Calibration of fiber optic sensor is incorrect
and will need recalibrated
Fiber optic lens is loose
Fiber optic sensor needs replaced
Fiber optic lens needs cleaned or replaced
Fiber optic cable has been damaged
Shank is larger than body of drill and cor-
rect diameter has not been manually input.
Example: Step drill
Symptom
Auto diameter detect will not detect cor-
rect diameter
Cause
Diameter detection rod is bent
Diameter detection rod has been improp-
erly installed. Refer to page 47
Incorrect diameter calibration
Shank of drill may be larger/smaller than
actually body of drill
Drill flutes are worn or damaged
MTO #1 button excessively worn
Symptom
Auto web detection does not display cor-
rect web thickness
Cause
Fiber optic sensor lens is dirty. Refer to
page 81
Fiber optic sensor is not calibrated cor-
rectly
Fiber optic sensor is bad
Old software installed
Symptom
Cutting edge is not positioned correctly
at 1:00
Cause
Chip on cutting edge
Burr on cutting edge
The fiber optic sensor has detected the
split line as cutting edge
Drill has a hook in the cutting edge – use
the Advance Screen to compensate. Refer
to page 39
Changing from extreme point angles. Ex-
ample: Converting a 180° drill into a 118°
point angle
Material build up on cutting edge
A value left in the Advance Screen
Trouble Shooting Section