User manual

Appendix C Common Questions
© National Instruments Corporation C-5 NI 6034E/6035E/6036E User Manual
function the connected signal serves. Use the Route Signal VI to enable the
PFI lines to output internal signals.
Caution
If you enable a PFI line for output, do not connect any external signal source to
it; if you do, you can damage the device, the computer, and the connected equipment.
What are the power-on states of the PFI and DIO lines on the I/O
connector?
At system power-on and reset, both the PFI and DIO lines are set to high
impedance by the hardware. This setting means that the device circuitry
is not actively driving the output either high or low. However, these lines
may have pullup or pulldown resistors connected to them as shown in
Table 4-2, I/O Signal Summary for the NI 6034E/6035E/6036E.These
resistors weakly pull the output to either a logic-high or logic-low state.
For example, DIO<0> is in the high-impedance state after power on, and
Table 4-2, I/O Signal Summary for the NI 6034E/6035E/6036E, shows the
50 kpullup resistor. This pullup resistor sets the DIO<0> pin to a logic
high when the output is in a high-impedance state.