User manual
Appendix A Specifications
© National Instruments Corporation A-9 NI 6034E/6035E/6036E User Manual
RTSI
Trigger lines ........................................... 7
Calibration
Recommended warm-up time ................ 15 minutes
Interval ................................................... 1 year
External Calibration reference ............... > 6 and < 10 V
Onboard calibration reference
Level ............................................... 5.000 V (±3.5 mV)
(over full operating temperature,
actual value stored in EEPROM)
Temperature coefficient.................. ±5 ppm/°Cmax
Long-term stability ......................... ±15 ppm/
Power Requirement
+5 VDC (±5%)....................................... 0.9 A
Note
Excludes power consumed through V
cc
available at the I/O connector.
Power available at I/O connector ........... +4.65 to +5.25 VDC at 1 A
Physical
Dimensions (not including connectors)
PCI devices ..................................... 17.5 by 10.6 cm (6.9 by 4.2 in.)
PXI devices ..................................... 16.0 by 10.0 cm (6.3 by 3.9 in.)
I/O connector.......................................... 68-pin male SCSI-II type
Environmental
Operating temperature............................ 0 to 55 °C
Storage temperature ............................... –20 to 70 °C
Humidity ................................................ 10 to 90% RH, non-condensing
1,000 h
UM.book Page 9 Monday, May 14, 2001 10:32 AM