User manual

Chapter 4 Connecting Signals
© National Instruments Corporation 4-21 NI 6034E/6035E/6036E User Manual
All digital timing connections are referenced to DGND. This reference
is demonstrated in Figure 4-10, which shows how to connect an external
TRIG1sourceandanexternalCONVERT*sourcetotwoPFIpinsonthe
NI 6034E/6035E/6036E device.
Figure 4-10. Timing I/O Connections
Programmable Function Input Connections
There are a total of 13 internal timing signals that you can externally control
from the PFI pins. The source for each of these signals is
software-selectable from any of the PFIs when you want external control.
This flexible routing scheme reduces the need to change the physical
wiring to the device I/O connector for different applications requiring
alternative wiring.
You can individually enable each of the PFI pins to output a specific
internal timing signal. For example, if you need the CONVERT* signal as
an output on the I/O connector, software can turn on the output driver for
the PFI2/CONVERT* pin. Be careful not to drive a PFI signal externally
when it is configured as an output.
TRIG1
Source
DGND
PFI0/TRIG1
PFI2/CONVERT*
CONVERT*
Source
I/O Connector
UM.book Page 21 Monday, May 14, 2001 10:32 AM