Product guide
12
Performance Notes
• All fog machines develop condensation around the output nozzle. Because this may result in some
moisture accumulation on the surface below the output nozzle, consider this condensation when
installing your unit.
• Fog machines may sputter small amounts of fog occasionally during operation and for a minute or so
after being turned off.
• All fog machines have a recycling period after bursts of fog, when the machine will shut itself down for
a short period in order to heat back up. During this time no fog can be produced.
Replacing a Fuse
Power surges, short-circuit or inappropriate electrical power supply may cause a fuse to burn out. If the
fuse burns out, the product will not function whatsoever. If this happens, follow the directions below to do
so.
1. Unplug the unit from electric power source.
2. Insert a flat-head screwdriver into a slot in the fuse cover. Turn the screwdriver to the left, at the same
time gently push a bit (Turn and Push). The fuse will come out.
3. Remove the used fuse. If brown or unclear, it is burned out.
4. Insert the replacement fuse into the holder where the old fuse was. Reinsert the fuse cover. Be sure to
use a fuse of the same type and specification. See the product specification label for details.
Troubleshooting
Showtec Atmos F-350 Fazer
This troubleshooting guide is meant to help solve simple problems.
Always monitor tank fluid level as you are fogging. Running a fog machine with no fluid can permanently
damage the unit.
If a problem occurs, carry out the steps below in sequence until a solution is found. Once the unit
operates properly, do not carry out following steps.
If the fazer does not operate properly, refer servicing to a technician.
1. If you experience low output, pump noise or no output at all, unplug immediately.
2. Check fluid level, the external fuse, remote connection, and power from the wall.
3. If all of the above appears to be O.K., plug the unit in again.
4. If fog does not come out after holding the remote button down for 30 seconds, check the hose
attached to the tank to make sure there is fluid going through the hose. Make sure the fazer isn’t
warming up.
5. If you are unable to determine the cause of the problem, do not simply continue pushing the remote
button, as this may damage the unit.
6. Return the machine to your Showtec dealer.
No Response to DMX
Response: Suspect the DMX cable or connectors, a controller malfunction, a light effect DMX card
malfunction.
1. Check the DMX cable: Unplug the unit; change the DMX cable; then reconnect to electrical power.
Try your DMX control again.
2. Determine whether the controller or light effect is at fault. Does the controller operate properly with
other DMX products ? If not, take the controller in for repair. If so, take the DMX cable and the light
effect to a qualified technician.
See next page for more problem solving.