IPS-AM ORDERCODE D6503
Congratulations! You have bought a great, innovative product from DAP Audio. The DAP Audio IPS-AM brings excitement to any venue. Whether you want simple plug-&-play action or a sophisticated show, this product provides the effect you need. You can rely on DAP Audio, for more excellent audio products. We design and manufacture professional audio equipment for the entertainment industry. New products are being launched regularly. We work hard to keep you, our customer, satisfied.
DAP Audio DAP Audio IPT-AM Guide Warning..…...................................................................................…………………………………………. Safety-instructions………………….……………………………………………………………….… Operating Determinations…………………………………………………………………………... Connecting to the mains……………………………………………………………………………. 2 2 4 4 Description..…..............................................................................……….………………………………… Features…………………………..……………………………………………….………………….…. Overview Front panel..…………..
WARNING CAUTION! Keep this system away from rain and moisture! FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! SAFETY INSTRUCTIONS Every person involved with the installation, operation and maintenance of this system have to: be qualified follow the instructions of this manual CAUTION! Be careful with your operations.
Make sure that the power-cord is never crimped or damaged. Check the system and the powercord from time to time. Make sure that the amplifier is turned down, before turning the power on or off. So you can avoid supersonic frequencies, which could damage your speakers. Don't put your equipment next to TV, radio, etc., because of interference or distortion. If you connect other parts of the system, be careful of ground loops.
OPERATING DETERMINATIONS If this system is operated in any other way, than the one described in this manual, the product may suffer damages and the warranty becomes void. Any other operation may lead to dangers like short-circuit, burns, electric shock, etc. You endanger your own safety and the safety of others! Connection with the mains Connect the device to the mains with the power-plug. Always pay attention, that the right color cable is connected to the right place.
Description of the device Features Intelligent fire alarm interface Auto activating function Minicomputer intelligent interface Up to neighbor +/-4 zones can be activated by inputting alarm signal Controllable 30 channels each set. Up to 120 channels can be controlled by using multiple units.
Front panel 1. AC Power Switch. This is the main Power switch. Press to turn the amplifier on. 2. Link Status Display. When operating the unit stand alone, the HOST LED lights up. If the unit is linked with other IPS-AM’s the LED’s will indicate following: HOST, controls CH1-CH30. SLAVE1, controls CH31-CH60. SLAVE2, controls CH61-CH90. SLAVE3, controls CH91-CH120. E.g. SLAVE 3 LED and CH12 LED light both up. This indicates that alarm CH102 is active. 3. Alarm Status Display.
Back panel 8. AC Inlet. This connector is meant for the connection of the supplied main cord. Connect one end of the power cord to the connector, the other end to the mains, then turn on the power switch (1) to operate the unit. Note: Please make sure that the supply voltage matches the operation voltage before connecting the unit to mains. 9. Fuse Holder 10. GND Screw. This screw offers a separate ground connection. Can be useful in case of grounding problems. 11. DC 24V Input.
17. Link Down Socket. This socket can be used if 30 alarm channels are not sufficient. Using the LINK UP and LINK DOWN sockets you can LINK several IPS-AM units to expand your channels. See also Chapter “Linking More Units” on page 10. 18. Or Gate Out Socket. As soon as any channel receives an alarm signal, the OR GATE OUT socket will be activated. Via the socket, you can output the alarm signal to activate for example an emergency alarm generator. 19. Alarm Output Socket.
Operation Installation Remove all packing materials from the IPS-WPT. Check that all foam and plastic padding is removed. Secure the equipment into a 19" rack. Connect all cables. Connecting the device Below an example of a possible setup. NOTE: Always turn off and disconnect the amplifier from mains voltage before making any connections.
Linking More Units. Your Alarm Matrix provides 30 preset alarm channels Linking up more devices allows you to control more than 30 alarm channels, if several units are linked, only the “OR GATE OUT” of the HOST is valid. Using The Active Up/ Active Down Dipswitches Using the active up/ active down DIP switches allows you to link up to +/-4 neighbor zones to an alarm channel. 1. 2. 3. 4.
Example 1: We want to Link 2 alarms up to each incoming alarm. The DIP switches should be set according the following diagram. In case of alarm on channel 14 an alarm will also be sent to channels 15 and 16. The according LED’s on the front panel will also light up red. Example 2: We want to Link 3 alarms up and 4 alarms down to each incoming alarm. The DIP switches should be set according the following diagram.
Audio connection Use the 6.3mm cable to connect the OR GATE OUT to REMOTE IN of an emergency alarm generator. As soon as the Alarm Matrix receives an alarm signal, the OR GATE OUT will send an alarm signal to activate the emergency alarm for alarming. OR GATE OUT REMOTE IN Alarm Matrix Emergency Alarm Maintenance The DAP Audio IPS-AM requires almost no maintenance. However, you should keep the unit clean. Disconnect the mains power supply, and then wipe the cover with a damp cloth.
Product Specifications Model Power supply Alarm Input Channel Power consumption Alarm Output Channel Input Logic Level Alarm Output Level Link Weight Dimension (LxWxD) Alarm Matrix AC 110-120/220-240V 50/60Hz 30ch Less then 18W 30ch +5 - 24V High Level Signal or 0V selectable 0V (Short) Up, Down +/- 4 Channel Extension 6.73kg (14.84lb) 483mm x 370mm x 88mm (19.02"x 14,57" x 3.46") Design and product specifications are subject to change without prior notice.
2007 Dap Audio.