Compact 9.2 Table of contents Warning ...............................................................................................................................................................................2 Unpacking Instructions .................................................................................................................................................2 Safety Instructions ..........................................................................................................
Compact 9.2 Warning FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Unpacking Instructions Immediately upon receiving this product, carefully unpack the carton and check the contents to ensure that all parts are present and have been received in good condition. Notify the dealer immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling. Save the carton and all packing materials.
Compact 9.2 IMPORTANT: The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorized modification to the system. Never let the power-cord come into contact with other cables! Handle the power-cord and all connections with the mains with particular caution! Never remove warning or informative labels from the unit. Never use anything to cover the ground contact.
Compact 9.2 Operating Determinations This system is not designed for permanent operation. Consistent operation breaks will ensure that the system will serve you for a long time without defects. If this system is operated in any other way, than the one described in this manual, the product may suffer damages and the warranty becomes void. Any other operation may lead to dangers like short-circuit, burns, electric shock, etc.
Compact 9.2 Description of the device Features 9 Channel 1U, 2 zones mixer The Compact 9.2 1U installation mixer is built to combine maximum audio possibilities and needs for a pub, school or public area without sacrificing on the ease of use. The user can adjust 3 microphone levels and 2 line levels. Both line levels have 6 selectable input sources which are shown on a clear display. On each line input it is possible to select a pre-programmed label, which is shown on the displays.
Compact 9.2 Overview Front Panel 1. Zone select button (Mic 1–3) Use these 2 switches to assign the channel to the zone A, zone B output or both. 2. Mic Volume control (mic 1–3) Controls the volume of the corresponding microphone channel. 3. Peak LED (mic 1–3) The peak LED shows signal peaks in a channel’s incoming signal. If the red peak LED frequently blinks or constantly lights, the corresponding channel is likely to enter clipping.
Compact 9.2 11. Aux in unbalanced mini jack input connector Unbalanced stereo mini jack aux input for connecting a line/phones level device. 12. Aux in unbalanced RCA input connectors Unbalanced stereo RCA aux input for connecting a line/phones level device. Note: When connecting signal sources, please make sure the corresponding channel faders and the master faders are at their minimum settings. Otherwise unpleasant plug-in noise can occur. 13.
Compact 9.2 Rear Panel 15. Power adapter connector This is the remote AC power supply input socket for the Compact 9.2. It is a special three core socket. only use the supplied DAP audio adapter. 16. Equalizer Section The microphone channel’s equalizer section allows shaping of the incoming audio signal. The high and low shelving controls have their frequencies fixed at 12KHz and 80Hz respectively. The mid range control has a peaking response frequency at 2,5KHz.
Compact 9.2 26. DIP Switch (Phantom power on/off / Hi-Pass 80Hz on/off) Left switch (Turn on/off Phantom power), right switch (Turn on/off the Hi-Pass filter) 27. Mic gain control (all MIC inputs) The microphone input level is determined by the gain control. With the gain control you are able to adjust the microphone input-sensitivity for an optimal match with the mixer’s internal operation level. 28.
Compact 9.2 Set Up and Operation Before plugging the unit in, always make sure that the power supply matches the product specification voltage. Do not attempt to operate a 115V specification product on 230V power, or vice versa. Connection Cables Take care of your cables, always holding them by the connectors and avoiding knots and twists when coiling them: This gives the advantage of increasing their life and reliability. Periodically check your cables.
Compact 9.
Compact 9.2 Maintenance The DAP Audio Compact 9.2 requires almost no maintenance. However, you should keep the unit clean. Disconnect the mains power supply, and then wipe the cover with a damp cloth. Do not immerse in liquid. Do not use alcohol or solvents. Keep connections clean. Disconnect electric power, and then wipe the audio connections with a damp cloth. Make sure connections are thoroughly dry before linking equipment or supplying electric power. Troubleshooting DAP Audio Compact 9.
Compact 9.2 Product Specifications Input channels: Output channels: Master EQ: Frequency response: T.H.D.: Powersupply: Powerconsumption: Dimensions: Weight: 3 x Microphone, combo XLR/Jack 6 x Line, RCA 1 x Phone, 3,5mm jack 2 x Master Balanced, XLR 80Hz, 2,5KHz, 12KHz, -6dB / +6dB 20Hz - 20Khz <0.01% 2x18V AC, 50Hz (Adapter included) 6 Watt 481x44x175mm (WxHxD) 2,2 Kg Design and product specifications are subject to change without prior notice.