EP HEAVY DUTY AUGER SERIES MODELS EP6 Hex, EP6 Round EP10 Hex, EP10 Round EP15 Hex, EP15 Round Owner: Date Purchased: Model #: Serial #: Manual #: DANGER Si no entiende ingles, se prefiere que busque a alguien que interprete las instrucciones para usted. 9MEP2456308 Operator’s Manual Danuser LLC 500 E. 3rd St. P.O. Box 368 Fulton, MO 65251 Tel: (573) 642-2246 Fax: (573) 642-2240 E-mail: sales@danuser.com Website: www.danuser.
Dear Owner/Operator, Thank you for purchasing this Danuser Hydraulic Earth Auger. We appreciate your business. Your safety as an operator of our product is very important to us. Therefore, before you assemble, install, operate, or maintain your Danuser Earth Auger, read and understand this manual thoroughly. If there is anything you do not understand, immediately contact your dealer, or contact our factory direct. Tel: Fax: E-mail: (573) 642-2246 (573) 642-2240 sales@danuser.
Foreword Please read this manual thoroughly! Before you assemble, install, operate, or maintain your Danuser Earth Auger, read this manual thoroughly. If there is anything you do not understand, immediately contact your dealer, or call our factory direct at (573) 642-2246. Powered equipment can be dangerous if not assembled, installed, operated, or maintained properly.
Safety WARNING Working with unfamiliar equipment can lead to careless injuries. Read and understand this manual and the manual for your vehicle before assembling, installing, operating, or maintaining this earth auger. If there is anything in this manual you do not understand, contact your dealer or Danuser LLC. The safe use of this machine is strictly up to you, the operator.
Safety (continued) • Do not allow riders on the equipment at any time. There is no safe place for any riders. • Never use alcoholic beverages or drugs which can hinder alertness or coordination while operating this equipment. Consult your doctor about operating this machine while taking prescription medications. • Consult local utility companies to make certain there are no buried gas lines, electrical cables, etc., in the work area before beginning operation.
Drive Unit Specifications EP6 EP10 EP15 Minimum Hydraulic Flow 6 GPM 10 GPM 15 GPM Maximum Hydraulic Flow 15 GPM 20 GPM 30 GPM Maximum Continuous Operating PSI 3000 PSI 3000 PSI 3000 PSI Maximum Auger Diameter 24 inches 30 inches 36 inches 2” Hex or 2-9/16" Round 2” Hex or 2-9/16" Round 2” Hex or 2-9/16" Round Output Spindle Model EP6 PSI 2000 2500 3000 TORQUE 1014 Ft.-Lbs. 1267 Ft.-Lbs. 1520 Ft.-Lbs. Model EP10 PSI 2000 2500 3000 TORQUE 1270 Ft.-Lbs. 1587 Ft.-Lbs. 1904 Ft.-Lbs.
Hydraulic Requirements Filtration Requirements: • A filter of, at least, 25 micron filtration is required. A filter capable of 10 micron filtration is preferred. The majority of paper type filters are 25 microns or better. NOTE The life of the hydraulic motor is almost entirely dependent upon cleanliness of the oil. Instructions in your vehicle operator’s manual regarding filter and oil changes should be carefully followed.
Assembly & Installation Drive unit and auger exploded views and part lists are detailed on separate pages in this manual. Skid-Steer Mount 1 = Safety Sign Location 4 10 9 5 3 6 2 12 7 8 11 Because of the weight of some components, and because some components are difficult to balance, two people are required for safe assembly and installation of this equipment.
Assembly & Installation Drive unit and auger exploded views and part lists are detailed on separate pages in this manual. Offset Skid-Steer Mount 1 = Safety Sign Location 7 6 2 5 3 9 4 8 Because of the weight of some components, and because some components are difficult to balance, two people are required for servicing of this equipment.
Assembly & Installation Drive unit and auger exploded views and part lists are detailed on separate pages in this manual. Offset Euro Mount = Safety Sign Location 1 7 6 2 3 9 5 4 8 Because of the weight of some components, and because some components are difficult to balance, two people are required for servicing of this equipment.
Assembly & Installation Mini-Excavator Mount 5 Drive unit and auger exploded views and part lists are detailed on separate pages in this manual. 7 2 REF. NO. PART NO. 1 ----2 10219 3 10193 4 20012 5 ----6 10220 7 6196 8 10038 10039 9 10041 10042 Because of the weight of some components, and because some components are difficult to balance, two people are required for safe assembly and installation of this equipment. DESCRIPTION QTY.
Assembly & Installation Drive unit and auger exploded views and part lists are detailed on separate pages in this manual. 7 TLB & Excavator Mount 5 REF. NO. PART NO. 1 ---- 2 10247 3 10193 4 20012 5 ---- 6 10242 7 10243 8 3092 9 10038 10039 10 10041 10042 DESCRIPTION 2 QTY. Drive Unit Knuckle Sub-Assembly Pin (1-1/4” x 9-1/2”) Lock Pin Ear Assembly Tube-Clamp Bolt (5/8” 11 x 2”) Nut (5/8” 11) Special Retaining Bolt - 2" Hex (3/4” 10 x 4”, Gr.
Assembly & Installation Drive unit and auger exploded views and part lists are detailed on separate pages in this manual. Bolt-on Bucket Mount 6 7 8 1 5 2 4 = Safety Sign Location 3 REF. NO. 10 Because of the weight of some components, and because some components are difficult to balance, two people are required for safe assembly and installation of this equipment.
Assembly & Installation (continued) STEP 5: Grease the inside of the auger collar liberally and attach the auger with the retaining bolt and nut that came attached to the drive unit spindle. This is a special thread length bolt - use genuine Danuser replacement parts only. For hex spindle, use Danuser PN 10038 (3/4” 10 x 4”, Gr. 8, 3/4” of thread) special retaining bolt and nut PN 10041. NEVER use a bolt longer than longer than 4". For round spindle, use Danuser PN 10039 (7/8” 9 x 4-1/4”, Gr.
Operation WARNING Read and understand this Operator’s Manual carefully before attempting to operate the Danuser Earth Auger. You are responsible for furnishing this manual to others who may use the unit. If you have any questions regarding the proper assembly, installation, or operation of this earth auger, contact your dealer or Danuser LLC. DANGER Serious injury or death can result from misuse of this equipment.
Operation (continued) STEP 6: The hydraulic flow rate or pressure should not exceed the earth auger’s specified maximums. The hydraulic minimums must be met to deliver satisfactory performance. Use only enough down pressure to assure positive penetration of the auger into the ground. Ease up on down pressure if auger rotation slows down drastically or stalls. Excessive down pressure will cause the auger to frequently stall.
Troubleshooting PROBLEM Slow Speed POSSIBLE CAUSE a) Low flow SOLUTION Check with flow meter. If low, investigate the cause. b) Fittings or connections are too small or incompatible c) Line restrictions d) Dirty oil or oil filter Replace with proper fittings. Clear lines. Change oil and oil filter according to vehicle manufacturer’s recommendation. e) Hydraulic pump worn See your dealer for repairs.
Maintenance DAILY CHECK PLANETARY GEAR OIL LEVEL Check oil level daily to assure proper lubrication is maintained. Check by removing the front fill plug - with the drive unit angled approximately 30 degrees from vertical. CHECK FOR CLEAN HYDRAULIC OIL The majority of all hydraulic component failures are caused by contamination of the hydraulic oil. At all times, keep dirt and other contaminates from entering the hydraulic system during connecting and disconnecting the hydraulic system.
Drive Unit Parts 2 14 3 13 = Safety Sign Location 4 6 7 1 5 8 9 10 12 REF. NO. PART NO. 1 10180 (H) 20180 (R) 10181 (H) 20181 (R) 10182 (H) 20182 (R) 2 10197 3 10192 4 20033 5 20034 6 10184 10185 10186 7 10482 8 10979 9 10183 20183 10 10196 11 10038 10039 12 10041 10042 13 10193 14 20012 15 10980 16 10996 10997 DESCRIPTION 15 QTY.
Decals & Safety Signs PART NO. DANUSER101 Locations: Quick Attach Plate, sides PART NO. DIG2 Location: Quick Attach Plate, top Model No. & Serial No. Location: Drive Unit, inside PART NO. DANUSER100 Location: Drive Unit, front PART NO. 9875 Location: Drive Unit, side PART NO. 10981 (EP6) PART NO. 10982 (EP10) PART NO. 10983 (EP15) Location: Drive Unit, front PART NO. DIG4 Location: Drive Unit, back PART NO. DIG3 Locations: Drive Unit, sides PART NO. DIG8 Location: Auger WARNING 20 PART NO.
Decals & Safety Signs (continued) WARNING Clean or replace all safety signs if they cannot be clearly read and understood. PART NO. DIG7 Location: Knuckle Ears, sides PART NO. DIG6 Location: Knuckle Ears, sides Mini-Excavator Knuckle TLB & Excavator Knuckle part no. DIG27 Location: Quick Attach Plate, top part no.
Augers & Accessories = Safety Sign Location AUGER ADAPTERS AUGER COLLAR 2” Hex 2-9/16" Rd. 10328 10329 VARIABLE LENGTH EXTENSIONS LENGTH 12” 24” 48” 72” 22 2” HEX --10900 10901 10902 2-9/16" RD. 10903 10904 10905 10906 Drive Unit 2” Hex 2” Hex 2-9/16" Rd. 2-9/16" Rd. to to to to Auger Collar 2-9/16” Rd. 2” Rd. 2" Hex 2" Rd. Part No. 10921 10922 10923 10924 FIXED LENGTH EXTENSIONS LENGTH 12” 24” 48” 72” 2” HEX 10910 10911 10912 10913 2-9/16" RD.
Augers & Accessories (continued) Fishtail Point Dirt Hardfaced Chunky Carbide Nut Bolt 4” diameter auger Dirt Hardfaced Chunky Carbide Nut Bolt 10331 10332 10335 10412 10413 below 10333 10334 10336 10412 10416 Teeth Bolt & Nut Carriage Bolt Nut 10410 10411 “FAB” AUGERS - 4’ Length DIA. NO. OF TEETH 2” HEX 2-9/16" RD.
Augers & Accessories “BULLET” ROCK AUGERS 4’ Length (continued) “Bullet” Rock Pilot Tooth Tooth Holder 10758 10759 10760 DIA. NO. OF TEETH 2” HEX 2-9/16" RD. 4.5” 6” 7” 8” 9” 10” 12” 14” 16” 18” 24” 30” 36” 4 6 8 8 8 10 12 14 16 18 22 24 30 10700 10703 10706 10709 10712 10715 10718 10721 10724 10727 10730 10733 10736 10701 10704 10707 10710 10713 10716 10719 10722 10725 10728 10731 10734 10737 WOBBLE AUGERS 4’ Length DIA.
This page is intentionally blank.
Warranty DANUSER LIMITED WARRANTY Model # Serial # Danuser LLC (“Danuser”) warrants its products, under normal use and maintenance, to be free from defects in material and workmanship for periods specified below from the purchase date from an authorized Danuser Dealer. Start of the warranty period is determined by purchase date given on your returned WARRANTY REGISTRATION FORM. Proof of purchase may be required. This Limited Warranty is extended only to the original purchaser of Danuser products.