Installation guide

REQUIREMENTS FOR VENT TERMINATION
EXHAUST
SYSTEMS
8
B Minimum 4 foot clearance below or beside any door or window which opens
C Minimum 1 foot clearance below or beside window that does not open
D Minimum 1 foot clearance above any door or window
E Minimum 3 foot clearance from any adjacent building or horizontally from combustible wall
F Minimum 1 foot clearance above grade
G Minimum 2 foot clearance above any grass, plants or other combustible materials
H Minimum 7 foot clearance above any grade when adjacent to public walkways
A Minimum 3 feet (36”) above the roof
and 2 feet (24”) above
the highest point of the roof within
10 feet
NOTE: VENT MAY NOT TERMINATE IN COVERED WALKWAY OR BREEZEWAY OR ABOVE
A SIDEWALK OR PAVED DRIVEWAY LOCATED BETWEEN TWO SINGLE FAMILY
DWELLINGS AND SERVES BOTH DWELLINGS
I Minimum 3 foot clearance from any forced air intake of any other appliance
J Minimum 4 foot clearance from a non-mechanical air supply inlet to the building or the
combustion air inlet to any other appliance
K Minimum 2 foot clearance below eaves or overhang
L Minimum 1 foot clearance to an outside corner from the center of the pipe
M Minimum 1 foot clearance to an inside corner
N Minimum 3 foot clearance above a gas meter/regulator assembly when measured from
the center line of the regulator
O Minimum 6 foot clearance to service regulator vent outlet
P Minimum 3 foot clearance under a veranda, porch, deck or balcony (NOTE: Only
permitted if veranda, porch, deck or balcony is fully open on sides beneath the floor)
Q *** VERY IMPORTANT ***: Minimum 1 foot beyond exterior wall for horizontal vent terminations
(extend further if outside wall has prevailing wind)
3’
10’
2’
A
O
G
F
K
L
DCBB
E
P
N
H
M
F
J
Q
I