Installation guide

EXHAUST
SYSTEMS
7
PELLET VENT TERMINATION
Termination must be a minimum of 6” above the chimney as shown at A (NOTE: Chimney must meet local
codes for height above the roof or other obstructions)
Vent termination must not be recessed into a wall or siding
NOTE: Where passage thru a wall or partition of combustible contruction is desired, the installation shall
conform to NFPA 211 in the USA and CAN/CSA B365 in Canada
There must be an approved cap to prevent water from entering the pipe shaft (
B),
or a 45 elbow downturn (
C)
If the termination is located on a windy side of the
house, an approved house shield is recommended
to prevent soot from accumulating on the side of
the house
There must be a metal seal plate or a wall
thimble at point
D
D
D
C
B
D
A
B
o
Termination must NOT be located where snow
or other materials will plug it
or