Full Product Manual

TROUBLESHOOTING GUIDE
1. Power Unit does not raise:
1.1 Verify electrical source matches motor specifications.
1.2 Verify breaker is not tripped or not working.
1.3 Verify correct voltage to motor.
2. The Power Unit runs but will not lift:
2.1 Check oil level.
2.2 Check that the lowering valve is not stuck open.
2.3 Check and verify all hose connections are complete.
3. The power unit raises the lift empty but will not lift a vehicle.
3.1 Make sure the vehicle is not above the rated capacity.
3.2 Clean the lowering valve by running the motor for 30 seconds while hold down the lowering
handle.
3.3 Check the motor voltage.
4. Lift drifts down:
4.1 Check for external leaks.
4.2 Clean the lowering valve by running the motor for 30 seconds while holding down the
lowering handle.
4.3 Clean the check valve seat.
5. Slow Lifting and or oil foaming up:
5.1 Check that oil used meets the specification in the Installation Instructions section of this
manual.
5.2 Tighten all hoses and fittings
6.
Anchors continually work loose:
6.1 Holes drilled too large, relocate the lift per the Installation Instructions section of this manual.
6.2 Floor is not sufficient to provide the necessary resistance. Remove an area of concrete and
repour as described in the Installation Instruction section in this manual.
7.
Lift does not raise and lower smoothly.
7.1 Reposition vehicle for a more even weight distribution.
7.2 Check to make sure all the columns are lubricated with white lithium grease, check for rough
edges/burrs and remove.
Page 27
For technical questions, please call 877.432.6627