STEP 7
(Wiring Hydraulic Power Unit)
1. Have a certified electrician run the power supply to
motor. Refer to the data plate found on the motor for
proper power supply and wire size.
WARNING!
DO NOT run power unit with no oil. Damage to pump can occur.
The power unit must be kept dry. Damage to power unit caused by water or other liquids such as
detergents, acid etc., is not covered under warranty.
Operate lift only between temperatures of 41°- 104° F.
Improper electrical hook-up can damage motor and will not be covered under warranty.
Motor can not run on 50HZ without a physical change in motor.
Use a separate breaker for each power unit.
Protect each circuit with time delay fuse or circuit breaker.
For 110-120 volt, single phase, use a 25 amp fuse.
DANGER!
ALL WIRING MUST BE PERFORMED
BY A LICENSED ELECTRICIAN.
DANGER!
DO NOT PERFORM ANY MAINTENANCE OR
INSTALLATION OF ANY COMPONENTS WITH OUT
FIRST ENSURING THAT ELECTRICAL POWER HAS
BEEN DISCONNECTED AT THE SOURCE OR PANEL
AND CANNOT BE RE-ENERGIZED UNTIL ALL
MAINTENANCE AND/OR INSTALLATION
PROCEDURES ARE COMPLETED.
WARNING!
RISK OF EXPLOSION!
This equipment has internal arcing or parts that
may spark and should not be exposed to flammable
vapors. Motor should not be located in a recessed
area or below floor level. NEVER expose motor to
rain or other damp environments. DAMAGE TO
MOTOR CAUSED BY WATER IS NOT COVERED
UNDER WARRANTY.