Full Product Manual
VISIT US ON THE WEB AT WWW.DANNMAR.COM18
EACH ARM RESTRAINT ASSEMBLY MUST BE INSPECTED AND ADJUSTED AS NEEDED BEFORE EACH
AND EVERY TIME THE LIFT IS OPERATED. DO NOT OPERATE THE LIFT IF ANY OF THE FOUR ARM RE-
STRAINT SYSTEMS ARE NOT FUNCTIONING PROPERLY. REPLACE ANY BROKEN COMPONENTS OR
COMPONENTS WITH BROKEN TEETH ONLY WITH AUTHORIZED OR APPROVED REPLACEMENT PARTS.
STEP 15
(Leveling Instructions)
1. Before operating your lift, check to make sure that both “A” and “B” measurements are equal.
(See figure 13)
2. Lift arms must be level before operation, if your lift arms are not level shim the columns as required.
(See figure 3 on page 12)
IMPORTANT NOTE:
The equalizer cables should be checked weekly for
equal tension. Failure to do this will cause uneven
lifting. The cables should always be adjusted so that
they are equal tension when resting on the safety
locks.
Fig: 11 Fig: 12
DANGER
A
B
Fig: 13