Full Product Manual
STEP 9
(Installing Hydraulic Lines)
1. Connect the straight side of the long hose to the power unit pressure port with a red plastic plug using
the 90 degree o-ring power unit fitting. Route the opposite side of the hose (90-degree side) through
the cylinder access hole in the back of the post, under the cylinder cradle and out to the middle of the
cover plate. (See figure 9)
2. Route the 2 short hoses from each cylinder to the center of the lift and connect them to the cylinder
using the 90 degree fittings provided. (See figure 9)
3. Connect all three hoses to the union tee provided under the middle of the cover plate and be sure the
hoses are routed in the middle of the cable path and tie off as needed to avoid any contact between
the hose and cable.
HOSE ROUTING DIAGRAM
Fig: 9
FOR TECHNICAL QUESTIONS, CALL (877)432-6627
15