Product Manual

24
STEP 13
Lift Removal
1. Depress the lowering valve on the power unit.
2. Ensure that the lift is lowered all the way to the ground.
3. Disconnect the power unit from the power source and / or ensure that the power to the circuit is shut
off to prevent accidental powering on of the lift while disassembling.
4. Disconnect the cylinder hoses from the cylinder. Hoses can be coiled and stored in the power unit cart.
Before removing cylinder hoses, always ensure that the hydraulic pressure has been relieved from the sys-
tem by depressing the lowering valve until the lift is fully lowered or the raised load is fully settled onto the
safety lock bars. Never connect or disconnect hoses with the lift in an elevated non-locked position.
Do not perform any maintenance or installation of any components with out first ensuring that electrical
power has been disconnected at the source or panel and cannot be re-energized until all maintenance
and / or installation procedures are completed.
5. Be careful to clean up any spilled hydraulic fluid that may drip from the hose assemblies.
6. Place the safety lock bars in the top column holes.
7. Remove the lift arm assemblies.
8. Loosen the anchor bolts . Be careful not to disturbed the lift column until ready to move the column.
9. Move the column to your storage area. Secure with straps or other device to prevent any accidental
tipping or movement of the columns during storage.
STEP 14
( Re-Installation )
1. Clear installation area of debris, tools and equipment.
2. Blow out the mounting holes with compressed air.
3. Inspect the dropin anchors for proper setting and the concrete for defects and / or damage.
4. Line up the holes of the Base Plates with the holes. Re-shim the lift as required to ensure the lift is
installed level.
5. With the Shims and Anchor Bolts in place, tighten all Anchor Bolts tight to the base plate.
DN use an impact wrench for this procedure.
6. Follow all procedures as outlined in steps 8 - 12.
Inspect all drop in anchors for proper setting and or damage each time the lift is re-installed. Inspect
the concrete for cracks defects and / or damage. Do not reinstall the lift if any of the dropin anchors
are defective or the concrete is cracked or defective.
DANGER
The lift must be re-leveled, shimmed and bled each time the lift is reinstalled. Failure to do so may

WARNING
DANGER