Product Manual

FOR TECHNICAL QUESTIONS, CALL
17
STEP 7
( CONNECTING HYDRAULIC LINES )
1. Thread the male quick disconnect fittings onto
the rear cylinder fittings using teflon tape on the
pipe threads. (See figure 16)
2. Thread one end of the male npt hose fitting into
one of the top ports of the flow divider.
Do this with both hoses.
figure 17)
3. Install the female quick-disconnect fittings at
each of the other male N hose ends.
(See figure18)
4. all fitting connections to make sure they are prop-
erly tightened before proceeding.
5. Position the power unit stand at the front or rear of the
vehicle.
6. Connect the free end of each cylinder hose assembly to the
quick disconnect fitting at the base of each cylinder.
(Seefigure 19)
STEP 8
( INSTALLING THE LIFT ARMS )
1.
Place the Lift Arm Assembly on the Lift Heads. Install the Lift Head Pins into the Lift Head and through
the holes in the Arm Assembly then press the external c-clip into place on the arm pin. (See figure 20 / 21 )
Male Quick
Disconnect
Fitting
Fig. 16
Female Quick
Disconnect
Fitting
Fig. 18
Fig. 17
Fig. 19
Fig. 20
Fig. 21
C-Clip