10. With the column firmly anchored, use the base plate as a guide, then drill pilot holes , , D E
approximately 2 deep using a rotary hammer drill and 5/8 concrete drill-bit.
11. Move the column out of the way.
12. Repeat previous steps 5 - 9 making sure the column base plate remains perfectly positioned over
each individual pilot hole.
13. If shimming is required, insert the shims as necessary under the
base plate so that when the provided 5/8 x 2 anchor bolts are
tightened, the columns will be plumb both side to side and front
to rear. (See figure 15)
14. With the shims and anchor bolts in place, tighten all 5/8 x 2
anchor bolts tight to the base plate . Turn 3 to 3-3/4 turns. Do not
use an impact wrench for this procedure.
NOTE:
IT WILL BE HELPFUL TO MARK ON OR OTHERWISE NOTE THE
LOCATION OF SHIMS USED AT EACH DROP ANCR TO ASSIST
AT TIME OF REINSTALLATION.
Fig. 15
A
B
LEVEL
IMPORTANT LEVELING INSTRUCTIONS
Before operating your lift, check to
make sure both “A” and “B” measure-
ments are equal.
The lift arms must be level before
operation. If your lift arms are not level,
shim the columns as required.
WARNING
Inspect all drop in anchors for proper setting and or damage each time the lift is re-installed. Inspect the
concrete for cracks defects and/or damage. Do not reinstall the lift if any of the dropin anchors are
defective or the concrete is cracked or defective.
It may be necessary to shim the columns to ensure that the columns are plumb. The columns must be
plumb and square or damage or injury may occur when using the lift. Do not exceed 1/4 total shim
thickness when using the supplied ropin anchors.
WARNING
WARNING
WWW..COM