Flowlight Booster Pump Specification Sheet
Filtration Requirement
This pump cannot tolerate dirt; water must be filtered
clear
Accessories
• Intake strainer/foot valve with fine monel metal
screen, stops coarse debris
• Inline filter (10”) uses standard drinking water
cartridges
• Intake filter/foot valve (30”) replaces Intake
Strainer and Inline Filter with a single unit, best for
lowering into a shallow well
• Spare filter cartridges (10 micron spun fiber)
• Easy Installation Kit includes: pressure switch,
pressure gauge, check, drain and shut-off valves
and tank tee (manifold)
• Dry run switch prevents battery drain and pump
damage if water source runs dry
Installation
• Pump may be mounted horizontally or vertically.
• Pump must not be submerged.
• It may be placed inside a 6” (120 cm) or larger
well casing, suspended by rope.
Dimensions
• Length 16.5” (42 cm)
• Weight 15 lbs (7 kg)
• Flexible hose ends have 3/4” or 1” male pipe
thread
Warranty
1 year against defects in materials and workmanship