Technical data

Local Display label description Valid units
KFCT2 - Frequency 2 K-factor BBL - Barrels
GAL - Gallons
L - Liters
CM - Cubic Meters
MCM - Thousand Cubic Meters
AO1 - Analog Output 1 current MA - Milliamperes
AO1 - Analog Output 2 current MA - Milliamperes
Note
When connected to a meter with the local display option, reverse flow direction is indicated with a
minus sign (negative) before the value(s) shown on the display.
Configure display units
The Meter volume units displayed are either U.S. Customary or Metric. To modify the
Display Units, configure the Meter units system in the Field Setup Wizard – General Page.
U.S. Customary volume unit selections are:
- Barrels
- Gallons
Metric volume unit selections are:
- Cubic meters
- Cubic liters
Display units preceded by a plus or minus sign indicate forward and reverse flow
direction, as shown in the table below.
The Local Display Flow rate time units are modifiable by selecting the drop-down
arrow and clicking the time unit in the list box.
Valid flow rate time units selections are:
- second
- minute
- hour
- day
Configure scroll delay
The Scroll Delay is the time interval for the selected display items to be shown on the Local
Display. The default scroll delay setting is five seconds. Click the spin box up or down arrow
to increase or decrease the length of time an item displays.
1.
Select Finish to write the configuration settings to the meter.
2. Save the meter configuration file, collect a Maintenance log and Waveforms to
document the “As Left” settings.
Daniel Liquid Ultrasonic Flow Meters calibration and configuration parameters
60 Daniel 3810 Series Operations Manual