Technical data
Configure local display parameters
Configure the parameters for the local display. Use the Field Setup Wizard drop-down
arrow in the Display Items list box and select or modify the Display items, the Display units
and the Scroll delay.
Local display parametersFigure 4-17:
Configure display items
Local Display label description Valid units
QFLOW - Uncorrected volume flow rate • BBL - Barrels
• GAL - Gallons
• L - Liters
• CM - Cubic Meters
• MCM - Thousand Cubic Meters
• GAL - Gallons
• CM - Cubic Meters
TDYVL - Current day's forward uncorrected volume • +BBL - Barrels
• +GAL - Gallons
• +L - Liters
• +CM - Cubic Meters
• +MCM - Thousand Cubic Meters
Daniel Liquid Ultrasonic Flow Meters calibration and configuration parameters
58 Daniel 3810 Series Operations Manual