Technical data

Appendix B
Miscellaneous equations
B Miscellaneous equations
B.1 Miscellaneous conversion factors
Use the following calculations:
K-factor - A read-only value showing the calculated K-factor from the Full scale
volumetric flow rate used with frequency outputs and the Maximum frequency for
frequency output. This property is disabled if Frequency outputs was cleared on the
Startup Page.
Vol/pulse - A read-only value showing the calculated inverse of the K-factor. This
property is disabled if Frequency outputs was cleared on the Startup Page.
Frequency Volumetric Flow Rate K-FactorFigure B-1:
Frequency Volumetric Flow Rate Inverse K-FactorFigure B-2:
KFactor
frequency “K-Factor” (pulses/m
3
or pulses/ft
3
) (Freq1KFactor and Freq2KFactor)
InvKFactor
frequency “Inverse K-Factor” (m
3
/pulse or ft3/pulse) (Freq1InvKFactor and
Freq2InvKFactor)
FreqQ
FullScale
frequency full-scale volumetric flow rate (m
3
/h or ft
3
/h)
(Freq1FullScaleVolFlowRate and Freq2FullScaleVolFlowRate)
MaxFreq
maximum frequency (Hz = pulses/s) (Either 1000 or 5000 Hz) (Freq1MaxFrequency
and Freq2MaxFrequency)
*TimeUnit: Time conversion factor depends on the VolFlowRate
volume/second = 1 s/s
volume/minute = 60 s/m
volume/hour = 3600 s/h
volume/day = 86400 s/d
Miscellaneous equations
Operations 115