User's Manual

4. EXAMPLE SETTING FROM SEMI TO MILLENNIUM
1. Turn off the marker before entering the setting mode and switch dip 1 to the OFF position
2. Pull and hold the trigger then press power button to turn on the marker. Release the power button then
trigger, the LED will be Red which indicates the Rate of Fire setpoint.
3. Pull trigger once to proceed to the next function selection mode, when the LED turns green then the functional
model will be at the Firing Mode. Press the POWER button once to enter the observation model which will
display the last setting. The LED will be ash the value that previous set.
• If pull the trigger at the observation mode then will be skip to the next function.
• If the original setting is at 4 then green LED 4 times, so on and so forth.
4. Follow-up to Step (3), then press POWER button once (LED will blink red green and yellow in a second
indicating of access to adjustable settings mode.
5. Following steps (4), in accordance with pulling the trigger 4 times (it will set the value to 4 [Millennium Mode].
Press the power button one time to indicate the set and to leave the adjustment mode back to Step 3
observation mode. The last settings well be reected in the blinking of the indicator light.
6. Then look at the other function whether or not to continue to choose or turned off board to leave the set mode.
RESET
To reset the marker to manufacturing default settings, press and hold down the trigger then press and hold down
the on/off button. Release the on/off button and hold on to the trigger for 10 seconds until yellow light appears.
PROGRAMMING YOUR G4 (CONTINUED)
Routine care and maintenance for your Dangerous Power G4 will ensure many years of high performance and
enjoyment. When in doubt, always seek the assistance of a certied technician from a reputable pro shop, or
contact Dangerous Power Customer Service.
DEGASSING the G4
Always be sure to completely de-gas your marker before performing maintenance or service repair. Carefully follow
the instructions below in sequence to ensure that all remaining air has been removed from the entire marker:
1. Flip the RAPS
TM
ASA to the ‘Off’ position. This disconnects the air system from the marker.
2. Remove the paintball loading device and check to make sure there are no paintballs within the breech.
3. Unscrew the air system from the RAPS
TM
ASA.
4. Point the marker in a safe direction, and then re 1-2 shots to remove air from the OPR. Be aware that the
marker may still re without any an air system attached.
5. Power OFF the marker.
CARE AND MAINTENANCE
W W W . D A N G E R O U S P O W E R . C O M
26 27