User's Manual
1. Locate screw underneath G3 Spec-R body, between OPR and Trigger Guard. Using (3/32”) allen key wrench,
loosen Connector Screw #1 by turning it counterclockwise. (SEE PIC A)
2. Locate Connector Screw #2 behind back cap. Using (3/32”) allen key wrench, loosen screw by turning it
counterclockwise. (SEE PIC B)
3. Separate the G3 Spec-R body from the trigger frame. (SEE PIC C)
SEPARATING G3 Spec-R BODY FROM TRIGGER
FRAME
B CA
SOLENOID MAINTENANCE
The G3 Spec-R solenoid is a delicate electronic component that requires minimal maintenance or service. DP
Engineering does not recommend frequent cleaning of this part, or its internals. The following instructions are
provided for reference and for expert airsmiths only.
1. Once the G3 Spec-R body and trigger frame are separated, locate the solenoid within the marker body. Note
the wiring harness connecting the solenoid to the main circuit board. (SEE PIC A)
2. Gently secure the base of the connectors and pull up to remove the plugs. DO SO ONE AT A TIME. It may
be helpful to use needle nose pliers. Note the location and direction of the connectors on the circuit board for
reassembly. (SEE PIC B . C)
3. With the connectors dislodged, turn the G3 Spec-R body so that the underside is facing up.
B CA
W W W . D A N G E R O U S P O W E R . C O M