User's Manual
3. CONFIGURATION MODE
• Setting Options as below:
Functionality
Mode
LED
Factory
Default
Min/Max
Rate Of Fire
Red 13 5/35
Firing Mode
Green 1 1/4
Ramp Point
Yellow 3 1/10
Trigger Debounce
Red Flash 10 1/20
Solenoid Dwell
Green Flash 12 5/25
ABS Dwell
Yellow Flash 4 1/4
▌ SOLENOID DWELL
This value controls the allotted time (in milliseconds) the solenoid is open. If too low, the marker will not cycle. If
the value is too high, the solenoid with remain open too long therefore wasting decreasing battery and air efciency.
▌ ABS DWELL
Adds an additional 1-3 milliseconds of dwell time to the programmed solenoid dwell setpoint on the rst shot of any
string of shots after a xed 20 seconds of shooting inactivity. A value of 4 disables the ABS Dwell feature.
Mode Description
Semi
First 1 shot per trigger pull.
PSP3
Three semi shots then transitions to 3 round bursts. Returns to semi mode after 1 second
of no activity.
NXL
Semi for the rst 3 shots, then fully automatic on the 4th shot. Rests to semi after 1
second of no activity.
Millennium
When triggering pull speed up to 8 BPS ramping will turn on at the 6 re, maximum re
rate can adjust at the ROF.
▌ FIRING MODE
PROGRAMMING YOUR G3 Spec-R (CONTINUED) PROGRAMMING YOUR G3 Spec-R (CONTINUED)
W W W . D A N G E R O U S P O W E R . C O M
22 23