User's Manual

Dangerous Powers G3/IQ Stock Board
B
ASE
F
IRING
M
ODES
Mode Description
Semi
Fires 1 shot for each trigger pull
PSP3
Three shots in Semi then transitions to 3 Round
Burst. Returns to Semi after 1 Second of no
activity.
NXL
Semi for the first 3 shots, then Full Automatic on
the 4th pull and hold. Resets to Semi after 1
second of no Activity
Millennium
Fires required three shots in Semi, then Semi
until transition to double rate of fire when trigger
pull rate >= Ramp Point. Resets to Semi after
trigger release or pull rate < Ramp Point.
M
ARKER
C
ONTROL
S
ETPOINTS
Feature LED
Default
Value
Min/Max
Value
MGRF
Red 13 5/25
Firing Mode
Green 1 1/4
Ramp Point
Yellow 3 1/10
Trigger Debounce
Red Flash 7 1/31
Solenoid Dwell
Green Flash 15 5/25
ABS Dwell
Yellow Flash 4 1/4
MARKER CONTROL SETPOINT DEFINITIONS
MGRF This sets the “Eyes On” Max Global Rate of Fire (in Balls per second) of all firing modes. A setting of 25 operates the marker in “Uncapped” mode for NPPL
semi tournament play. PSP and NXL formats require 13 BPS,/ Millennium requires 12 BPS. User is responsible for legal program settings.
Firing Mode This value determines the Power On Firing Mode of the marker. 1 = Semi, 2 = PSP3, 3 = NXL, 4 = Millennium. User is responsible for legal program
settings.
Ramp PointDetermines the ramping point of the currently assigned Firing Mode. Tournament legal setting is 3 for PSP/NXL modes / 6 for Millennium Mode. User
is responsible for legal program settings.
Trigger Debounce
This value sets amount of time (in milliseconds) the trigger must remain inactive prior to accepting a new trigger pull. It can
also control the trigger optical sensitivity. A debounce value of 1-15 provides the most sensitive optical trigger operation, and a debounce time
proportional to the setpoint. A value of 16-31 provides a less sensitive trigger (requiring more physical travel across the optical sensor), and a
debounce time equal to the setpoint value minus 15 (example: setpoint value of 25 = debounce of 10ms / 25-10 = 10).
Solenoid Dwell This value controls the amount of time (in milliseconds) the solenoid is energized. If too low, the marker will not cycle. If the value is too high, the
solenoid remains on too long, wasting battery power and air.
ABS Dwell Adds an additional 1-3 milliseconds of dwell time to the programmed solenoid dwell setpoint on the first shot of any string of shots after a fixed 20
seconds of shooting inactivity. A value of 4 disables the ABS Dwell feature.
NON-ADJUSTABLE FEATURES (ALWAYS ON):
MGRF Eyes OFF – When the Eyes are shutoff, the MGRF is overridden to 10 BPS.
Breech/Eye Delay This value controls the amount of time (in milliseconds) the eyes must see a ball in the breech prior to cycling the bolt. This will be a fixed 3
milliseconds and will compensate for different paint grades and feed methods. This delay will be run in series with all the bolt related timing.
Auto Shutoff – The marker will shut off automatically after 20 minutes of NO firing activity.
Trigger Buffering - This buffers a trigger pull during the bolt cycle, resulting in your marker firing more smoothly in all modes.
Battery Monitor – Sampled only when Power Button is pressed to conserve overall battery life.
P
OWER
B
UTTON
P
OWER
ON
P
RESS
/H
OLD
UNTIL
LED
ILLUMINATES
(
DISPLAYS
BATTERY
LEVEL
). R
ELEASE
AND
MARKER
IS
READY
TO
FIRE
.
P
OWER
OFF
P
RESS
/H
OLD
2 S
ECONDS
U
NTIL
LED
TURNS
OFF
. R
ELEASE
AND
MARKER
IS
O
FF
.
E
YE
C
ONTROL
T
AP
TO
T
OGGLE
EYE
DISABLE
/
ENABLE
.
LED
P
OWER
ON
B
ATTERY
L
EVEL
OK (
GREEN
F
LICKER
), L
OW
B
ATTERY
L
EVEL
(
RED
F
LICKER
)
F
IRING
O
PERATIONS
S
OLID
G
REEN
(
BALL
IN
BREECH
/ M
ARKER
LOADED
)
S
LOW
G
REEN
(
EMPTY
BREECH
/ M
ARKER
N
OT
LOADED
)
F
AST
G
REEN
(E
YES
O
FF
)
T
RIGGER
F
IRING
M
ODE
O
PERATION
I
N
F
IRING
M
ODE
,
FIRES
THE
MARKER
. I
NVOKES
PROGRAMMING
MODE
AT
P
OWER
U
P
.
P
ROGRAMMING
M
ODE
O
PERATION
I
N
P
ROGRAMMING
M
ODE
, C
YCLES
THROUGH
S
ETPOINTS
AND
E
NTERS
S
ETPOINT
VALUES
VIA
TRIGGER
PULLS
.
P
ROGRAMMING
E
XAMPLE
Setting the Firing Mode to PSP3 from Default
SEMI mode:
1. Start Programming Mode
2. LED is SOLID RED (MGRF setpoint). Pull trig-
ger to scroll to next setpoint.
3. LED is SOLID GREEN (Firing Mode setpoint).
Tap the power button to select this setpoint.
4. LED flashes current value repeatedly. Tap
power button again to reprogram this setpoint.
5. Pull the trigger 2 times, observing 1 LED flash
per pull
6. Tap the power button once more to save the
new setpoint value.
7. Returns to Step 4.
8. Pull trigger to scroll to another setpoint or power
off marker.
F
OR
HELP
WITH
YOUR
NEW
D
ANGEROUS
P
OWER
G3/IQ
BOARDS
,
PLEASE
CONTACT
US
AT
:
S
UPPORT
@D
ANGEROUS
P
OWER
.
COM
O
R
C
ALL
(909)869-7800

Summary of content (1 pages)