RAPS™ FLIP LEVER ASA
REMOVAL AND MAINTENANCE
The RAPS
TM
ASA was designed to be virtually maintenance
free. However, it may be necessary to occasionally clean and
inspect for debris or damage, as either may cause malfunction
or leaking of air.
1. Remove macro-line from RAPS
TM
ASA.
2. Remove buttery grip panels from trigger frame.
3. Disconnect solenoid wiring harness and eye wiring
harness from circuit board.
4. Locate the three screws securing circuit board to trigger
frame and unscrew using a crosshead (Phillips)
screwdriver. Carefully remove the circuit board from the
trigger frame.
RAPS™ FLIP LEVER ASA
REMOVAL AND MAINTENANCE (CONTINUED)
5. Locate front and back screws within grip frame as
illustrated, and unscrew with (3/32”) allen key wrench.
6. Slide RAPS
TM
ASA forward on rail to remove from frame.
7. Locate hex screw on RAPS
TM
ASA casing.
8. Using (5/64”) allen key wrench, loosen and remove screw
by turning it counterclockwise.
9. Remove RAPS
TM
lever and piston from RAPS
TM
casing as
shown.
10. Check spring for proper tension. Replace if worn or
damaged.
A
C
B
G
D
F
E